摘要
通过对YG—75/5.4—M21循环流化床锅炉投产后出现的灭火、局部结焦、床温偏差、负荷率低等问题进行的分析,针对锅炉在运行方式、设备维护、设备状况等方面存在的缺陷和不足,提出了合理的解决办法和建议。
Through analysis on the problems of the engine's cutting out, partial agglomeration, bed temperature deviation, and lower duty ratio, etc., and in the light of the demerits and shortages existing in the operation mode, equipment maintenance, equipment condition, etc., this paper puts forward some rational solving methods and suggestions.
出处
《科技情报开发与经济》
2005年第1期146-147,共2页
Sci-Tech Information Development & Economy
关键词
循环流化床锅炉
床温偏差
出力
cyclic fluidized bed boiler
bed temperature deviation
service