期刊文献+

纳秒级不同脉宽的信号对电容分压器的影响 被引量:13

Influence of Different Input Signals with Nanosecond Pulsewidth on Capacitive Voltage Divider
下载PDF
导出
摘要 为选择和设计适用的电容分压器以完善测量系统 ,先简析了电容分压器测量不同脉宽信号的不同结果 ,再研制了自积分模式电容分压器 (分压比为 1370 ,方波脉冲响应时间 0 .6 5ns)来测量脉宽分别为 10 0和 10ns的信号 ,实验结果与理论分析一致。 The capacitive voltage divider is now being widely used in laboratories to monitor the high voltage pulses in the fields of Pulsed Power Technology and HPM. It has fast response time and few influence on operating system. This paper presents the theoretical analysis for the different measuring results with different pulse width of the signals. A capacitive voltage divider with self-integral mode is designed. The attenuation ratio is 1370 and the response time is 0.65 ns. The signals with the pulse width of 100 ns and 10 ns are measured by this divider. The experimental result accords with the theoretical analysis.
出处 《高电压技术》 EI CAS CSCD 北大核心 2004年第12期42-44,共3页 High Voltage Engineering
关键词 电容分压器 微分信号 响应时间 方波脉冲 capacitive voltage divider differential signal response time step pulse
  • 相关文献

参考文献5

  • 1[2]沈龙根.脉冲功率技术基础[C].长沙:国防科技大学应用物理系,1989.
  • 2[3]梁曦东,关志成,陈昌渔.高电压工程[C].北京:清华大学电机工程与应用电子技术系,2000.
  • 3[4]华中工学院与上海交大合编.高电压实验技术[M].北京:水利水电出版社,1982.
  • 4阿·施瓦伯.高电压测量技术[M].北京:电力工业出版社,1982..
  • 5[7]怀武龙.电容分压器在Tesla变压器型电子束加速器中的应用[D].长沙:国防科技大学,1999.

共引文献2

同被引文献98

引证文献13

二级引证文献78

相关作者