摘要
催化分析法是以微量元素作为催化剂来测定微量元素的一种定量分析方法。本文采用催化分析法对铁的定量分析进行了研究。740mm附近的吸收峰是试剂完全反应的结果,而520mm附近的吸收峰是过量试剂反应的结果。因此,应在740mm处测定。
A highly sensitive catalytic method is proposed for the determination of iron. The reaction is catalyzed by trace amounts of iron. The absorption Peak at 740nm is the result of exhaustive reaction of reagent. But, the ab- sorption peak at 520nm is the result of reaction by excess reagent. lt has to determinate at 740nm.
出处
《淮阴工学院学报》
CAS
2001年第3期16-19,共4页
Journal of Huaiyin Institute of Technology
关键词
催化分析
微量铁
甲氧基苯胺
过氧化氢
二甲基苯胺
catalytic method, trace amounts of iron, anisidine, dimethylaniline, hydrogen peroxide, phenanthroline