摘要
通过3吨电弧炉能量收支情况比较分析,找出热损失的关键点—电炉短网,并有针对性地提出改造方案。
A study with the comparison between input and expenditure of energy in a three-ton arc furnace, has found that a short network is the key solution to the heat loss, and a renovation scheme is given for reference.
出处
《四川理工学院学报(自然科学版)》
CAS
2004年第3期39-43,共5页
Journal of Sichuan University of Science & Engineering(Natural Science Edition)