氢同位素分离装置测控软件的优化 被引量:2

Optimization of Measure-Control Software for Hydrogen Isotope Separation Device
下载PDF
导出
摘要 氢同位素分离装置测控软件的优化包括配置保存和准确计时优化。配置保存优化是将当前配置数据作为界面元素的默认值进行保留,软件运行时自动加载用户上次保存的配置数据。相关程序用.vi访问“系统主控.vi”的Config.log,获取所有配置数据,“系统主控.vi”捕获配置列表,确定加载配置数据。准确计时优化采用 Tick Count函 数 获 取 相 对 时 间 , 处 理 Wrap-back 时 间 基 点 和 时 间 差 值 以 避 免 计 时 误 差 的 累 积 。 Measure-control software of hydrogen isotope separation device is optimised with set up-conservancy and record-time optimization. Set up-conservancy optimisation is that current configuration data used as the default of interface element is saved. The configuration data that was saved by customer in last time was auto loaded when software was ran every. Config.log of system main control .vi was accessed with .vi for correlative program to obtain all configuration data. System main control .vi captured configuration list, and confirmed loading configuration data. Record-time optimisation is that relative time is captured and Wrap-back time basic point and time error is processed with Tick Count function to avoid cumulation of timing error.
出处 《兵工自动化》 2004年第6期89-90,92,共3页 Ordnance Industry Automation
关键词 软件优化 测控软件 配置保存 计时优化:氢同住素 Software optimisation Measure-control software Set up-conservancy Record-time optimisation Hydrogen isotope
  • 相关文献

参考文献1

  • 1[1]Nobuyuki N, Junya Y, Ryusuke K, etc. Rate of Isotope Exchange Rcaction between Tritiated Water in a Gas Phase and Water on the Surface of Piping Materials [J].Fusion Technology, 2001, (39): 189-197.