摘要
对泵站的电耗因素进行了分析,指出富裕扬程和效率偏差是泵站浪费的主要原因。富裕扬程可以用调速手段解决;效率偏差是目前需要解决的问题,文章对此进行了讨论。该文的重点是讨论泵站节能的判别准则,并对泵站节能标准的建立进行了探讨。
Through analying electric power of pump station ,this paper points out that the extra lift and efficency deviation in pump station is main reasons of waste. Speed regulating method can resolve extra lift,but the efficency deviation is a problem that needs to be resolved now.《PumpSave 3.0》 software can resolve above problem. The software can determine the lowest electric power per ton water in the pump station and give out a optimizing run methed. Especially some judgement methods are given in the paper to energy-saving work of pump station. The possibility of establishing energy-saving criterion is studied also.
出处
《排灌机械》
2004年第6期37-40,共4页
Drainage and Irrigation Machinery