期刊文献+

低注量X射线中屏蔽电缆的系统电磁脉冲响应研究 被引量:1

Research for SGEMP response of shield-cable in low-flux X-ray radiation
下载PDF
导出
摘要 介绍了在低注量X光条件下进行电缆的系统电磁脉冲实验研究的方法。将DPF低注量脉冲X光响应实验与实验室电流注入方法相结合,对典型实用电缆的系统电磁脉冲响应情况进行了实验研究,结果表明该方法对于电缆的研究是切实可行的,克服了由于缺乏高注量X光装置带来的困难。 The technology for shield-cable SGEMP response in low X-ray radiation was introduced,the SGEMP response for representative-cable was researched with two way which includes the experiment of X-ray response in DPF low flux X-ray radiation and the experiment of current- injection in laboratory.The result shows that research way is applicable for cable response research,and the difficulty by lack of high-flux X-ray was solved
出处 《核电子学与探测技术》 CAS CSCD 北大核心 2005年第1期100-103,共4页 Nuclear Electronics & Detection Technology
关键词 系统电磁脉冲 电缆 脉冲X光 三同轴注入系统 SGEMP cable pulse X-ray three-Co-axis inject system
  • 相关文献

参考文献3

  • 1钟玉芬 等.DPF-X光源编织屏蔽电缆辐照效应研究[C]..第9届全国核电子学与核探测技术学术年会论文集[C].扬州,1999.239.
  • 2钟玉芬,程引会,周辉,李宝忠,吴燕玲.电流注入法模拟双电缆系统的X光辐照效应实验研究[J].核电子学与探测技术,2000,20(2):134-137. 被引量:6
  • 3李宝忠 等.编织屏蔽电缆EMP耦合和X光响应的理论计算[C]..计算物理陕西分会第1届学术会议论文集[C].,1998.72.

二级参考文献1

  • 1[1]Vance.Coupling to shielded cable.John Wiley and Sons,Ny 1978.

共引文献5