期刊文献+

LASIK术后眼压测量值的变化分析 被引量:5

原文传递
导出
摘要 目的 探讨与准分子激光原位角膜磨镶术 (laserinsitukeratomileusis ,LASIK )治疗近视眼术后眼压测量值改变有关的各种相关因素。方法  5 4例 (10 3只眼 )中高度近视患者按屈光度分成A组 (≥ -3 0D ,<-6 0D)和B组 (≥ -6 0D) ,施行LASIK术前、术后 3月后用非接触式眼压计 (non -contacttonometer ,NCT)测量眼压 ,角膜地形图仪测量角膜前表面曲率 ,超声角膜测厚仪测量中央角膜厚度 (centralcornealthickness ,CCT)。对眼压差与CCT差、角膜曲率差、术前近视度数、术前散光度数、所矫正的等值球镜度数、切削深度、切削直径、年龄、性别、眼别等因素进行相关分析和多元逐步回归分析。结果 A、B两组间术前眼压、术前CCT、术后角膜曲率、术后CCT有显著性差异 (分别为P =0 0 11,P =0 0 3 1,P <0 0 0 1,P =0 0 0 1) ,术前曲率及术后眼压无显著性差异 (分别为P =0 5 5 0 ,P =0 0 91)。相关分析显示眼压差与CCT差、角膜曲率差、术前近视度数、所矫正的等值球镜度数、切削深度有显著相关性 (分别为P <0 0 0 1,P =0 0 2 7,P <0 0 0 1,P <0 0 0 1,P <0 0 0 1) ,与年龄、术前散光度数、切削直径无显著相关性 (分别为P =0 90 4,P =0 180 ,P =0 461)。男、女性之间的眼压差有显著性差异 (P <0 0 0 1)
出处 《中国实用眼科杂志》 CSCD 北大核心 2004年第12期989-992,共4页 Chinese Journal of Practical Ophthalmology
  • 相关文献

参考文献13

  • 1Hirano S, Sagara K, Suzuki K, et al. Implication of corneal thickness on different intraocular pressure readings between non - contact and applanation tonometer. Jap J Clin Ophthalmol, 2000, 54:1127~1130
  • 2钟一声,龚洁,叶纹,王康孙.非接触式眼压计与Goldm ann压平眼压计测量眼压的比较[J].眼视光学杂志,2000,2(2):101-103. 被引量:32
  • 3Graf M. Significance of the corneal thickness in non - contact tonometry. KlinMonatsbl Augenheilkd, 1991, 199:183~186
  • 4Theo S, Matihias D, Thoai P. Repeated excimer laser treatment after photorefractive keratectomy. Arch Ophthalmol, 1992, 110:1231
  • 5Emara B, Probst L E, Tigney D P, et al. Correlation of intraocular pressure and central corneal thickness in normal myopic eyes and after laser in situ keratomileusis. J Cataract Refract Surg, 1998, 24:1320~1325
  • 6Park H J, Uhm K B, Hong C. Reduction in intraocular pressure after laser in situ keratomileusis. J Cataract Refract Surg, 2001, 27:303 ~ 309
  • 7C ennamo G, Rosa N, La Rana A, et al. Non - contact tonometry in patients that underwent photorefractive keratectomy. Ophthalmologia, 1997, 211:341~343
  • 8Rosa N, Cennamo G, Breve M A, et al. Goldmann applanation tonometry after myopic photorefractive keratectomy. Acta Ophthalmol. Scand, 1998, 76:550~554
  • 9Chatterjee A, Shah S, Bessant D A. Reduction in intraocular pressure after excimer laser photorefractive keratectomy. Ophthalmology,1997, 104:335~339
  • 10Arimoto A, Shimizu K, Shoji N, et al. Underestimation of intraocular pressure in eye after laser in situ keratomileusis. Jpn J Ophthalmol, 2002, 46:645~649

二级参考文献13

  • 1胡茂生 刘淳诗.非接触式眼压计与Goldmann氏压平眼压计对比研究[J].中华眼科杂志,1985,:111-111.
  • 2王蓉芳 郭秉宽 等.高度近视与原发性开角型青光眼[J].中华眼科杂志,1986,22(6):243-243.
  • 3ShieldsMB.Thenon-contacttonometer.Itsvalueandlimitations[J].SurvOphFthalmol,1980,24:211.
  • 4施益浩.非接触眼压计正常眼眼压测定[J].中华眼科杂志,.
  • 581,17:211-213.
  • 6EhlersN,BramsenT,SperlingS.Applanationtonometryandcentralcornealthickness[J].ActaOphthalmol,1975,53:34-43.
  • 7JohnsonM,KassMA,MosesRA,etal.Increasedcornealthi-cknesssimulatingelevatedintraocularpressure[J].ArchOphthalmol,1978,96:664.
  • 8WhitacreMM,SteinRA,HassaneinK.Theeffectofcornealthicknessonapplanationtonometry[J].AmJOphthalmol,1993,115:592-596.
  • 9WhitacreMM,SteinRA,HassaneinK.Theeffectofcornealthicknessonapplanationtonometry[J].AmJOphthalmol,1993,115:592-596.
  • 10ChatterjeeA,ShahS,BessantDA,etal.Reductioninintraocularpressureafterexcimerlaserphotorefractivekeratectomycorrelationwithpretreatmentmyopia[J].Ophthalmology,1997,104(3):355-359.

共引文献63

同被引文献37

引证文献5

二级引证文献9