期刊文献+

Venous hemodynamic changes of lower extremity during gynecological laparoscopy

Venous hemodynamic changes of lower extremity during gynecological lapa- roscopy
下载PDF
导出
摘要 To study the effect of CO2 pneumoperitoneum and the special 30 degree head-down tilt positionon the venous hemodynamics in the lower extremity. Methods: Color doplex ultrasound was adopted to evaluate the diameterand blood flow velocity of the right femoral vein of 18 patients undergoing gynecologic laparoscopy under the same pressure ofpneumoperitoneum of 12 mmHg. The diameter of femoral vein and the flow velocity were measured; the blood flow volumewas calculated based on the equation of Q = vπr2 . Result: After establishment of pneumoperitoneum, the dilation of the fem-oral vein and the decrease in the velocity and volume can be observed (P < 0.05). And the 30 degree head-down positioncould increase the flow velocity and volume of the femoral vein and decrease the diameter of the vessel ( P < 0.05). At 30minutes of the 30 degree head-down tilt position, the blood flow ameliorated compared with that in prone position after theestablishment of pneumoperitoneum. After deflation of pneumoperitoneum, the femoral vein remained dilated( P < 0.05 ).Conclusion: During laparoscopy, CO2 pneumoperitoneum may result in the dilation of the vein in lower extremity and retar-dance of blood flow. The 30 degree Trendlenburg position can ameliorate the blood flow in the lower extremity. The deflationof the pneumoperitoneum cannot eliminate the effect of CO2 pneumoperitoneum on the lower extremity veins, which may pre-dispose deep venous thrombosis after laparoscopy. Objective: To study the effect of CO2 pneumoperitoneum and the special 30 degree head-down tilt position on the venous hemodynamics in the lower extremity. Methods: Color doplex ultrasound was adopted to evaluate the diameter and blood flow velocity of the right femoral vein of 18 patients undergoing gynecologic laparoscopy under the same pressure of pneumoperitoneum of 12 mmHg. The diameter of femoral vein and the flow velocity were measured; the blood flow volume was calculated based on the equation of Q = vπr2 . Result: After establishment of pneumoperitoneum, the dilation of the femoral vein and the decrease in the velocity and volume can be observed (P < 0.05). And the 30 degree head-down position could increase the flow velocity and volume of the femoral vein and decrease the diameter of the vessel ( P < 0.05). At 30 minutes of the 30 degree head-down tilt position, the blood flow ameliorated compared with that in prone position after the establishment of pneumoperitoneum. After deflation of pneumoperitoneum, the femoral vein remained dilated( P < 0. 05). Conclusion: During laparoscopy, CO2 pneumoperitoneum may result in the dilation of the vein in lower extremity and retar dance of blood flow. The 30 degree Trendlenburg position can ameliorate the blood flow in the lower extremity. The deflation of the pneumoperitoneum cannot eliminate the effect of CO2 pneumoperitoneum on the lower extremity veins, which may predispose deep venous thrombosis after laparoscopy.
出处 《Journal of Medical Colleges of PLA(China)》 CAS 2004年第6期363-366,共4页 中国人民解放军军医大学学报(英文版)
关键词 股静脉 血流动力学变化 妇产科 腹腔镜 腹腔积气 pneumoperitoneum laparoscopy femoral vein hemodynamics
  • 相关文献

参考文献11

  • 1[1]Sobolewski AP, Deshmukh RM, Brunson BL et al. Venous hemodynamic changes during laparoscopic cholecystectomy [ J ]. J Laparoendosc Surg,1995; 5(6): 363.
  • 2[2]Patel MI, Hardman DT, Nicholls D et al. The incidence of deep venous thrombosis after laparoscopic cholecystectomy[J]. Med J Aust, 1996; 164(11): 652, 656.
  • 3[4]Myre K, Rostrup M, Buanes T et al. Plasma catecholamines and haemodynamic changes during pneumoperitoneum [ J ]. Acta Anaesthesiol Scand,1998; 42(3): 343.
  • 4[5]Moneta GL, Bedford G, Beach K et al. Duplex ultrasound assessment of venous diameters, peak velocities, and flow patterns[J]. J Vasc Surg,1988; 8(3): 286.
  • 5[6]Jorgensen JO, Hanel K, Lalak NJ et al. Thromboembolic complications of laparoscopic cholecystectomy[J]. Br Med J, 1993; 306(4): 518.
  • 6[7]Catheline JM, Capelluto E, Gaillard JL et al. Thromboembolism prophylaxis and incidence of thromboembolic complications after laparoscopic surgery[J]. Int J Surg Investig , 2000; 2(1): 41.
  • 7[8]Kakkar VV. Pathophysiologic characteristics of venous thrombosis[J]. Am JSurg, 1985; 8 150(4A): 1.
  • 8[11]Maillo CL, Martin E, Lopez J et al. Effect of pneumoperitoneum on venous hemodynamics during laparoscopic cholecystectomy. Influence of patients' age and time of surgery[J]. Med Clin Barc, 2003; 20(9): 330.
  • 9[12]Caprini JA, Arcelus JI, Laubach M et al. Postoperative hypercoagulability and deep-vein thrombosis after laparoscopic cholecystectomy[ J]. Surg Endosc, 1995; 9(3): 304.
  • 10[13]Clark C, Cotton LT. Blood-flow in deep veins of leg recording technique and evaluation of methods to increase flow during operation [ J ]. Br J Surg, 1968; 55(3): 211.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部