摘要
潜在震源区的确定是核电厂选址工作过程中的一项极为重要的工作内容。目前 ,在实际工作中基本上是采用定性描述方法确定潜在震源区。本文以辽宁核电厂为例 ,采用有限元模拟计算方法确定潜在震源区 ,是潜在震源区研究的一种新尝试。
The determining source area of potential earthquake is a very important task during unclear power plant sitting.At the moment,the source areas of potential earthquake are determined by the way of qualitative describing in practical work.In this paper,the finite element method is used to determine the source areas of potential earthquake of Liaoning nuclear power plant
出处
《电力勘测设计》
2000年第1期26-29,共4页
Electric Power Survey & Design
关键词
潜在震源区
有限元
核电厂
source area of potential earthquake
finite element method
nuclear power plant