摘要 目的 对聚 -L -乳酸 /羟基磷灰石复合材料 (HA/PLLA)颈椎椎间融合器进行山羊颈椎融合试验研究。方法  12只成年雄性山羊 ,支气管内麻醉 ,于C3、4椎间隙植入HA/PLLA颈椎椎间融合器 ,术后 3、 6、 9、 12个月进行放射学观察、生物力学评价。结果  12只雄性山羊均存活良好 ,术后即开始正常行走 ,未见明显神经系统并发症 ,体重、饮食均无异常 ,术后 12个月所有山羊均发生了融合 (3级 ) ,融合率明显高于钛合金颈椎椎间融合器组。结论 可吸收颈椎椎间融合器具有并发症少、融合率高、人工可吸收等特点 ,是今后较理想的颈椎融合材料。 Objective To evaluate a new biorsorbable cervical fusion cage.Methods Twelve mature goats underwent a cervical interbody fusion procedure (C 3、4 ).Two types of custom-made cage devices were impacted with bone graft and implanted: HA/poly-L-lactic acid cages (n=6)and Titanium cage(n=6).Results In HA/PLLA specimens,permanent interbody fusion could be achieved within 6 month after surgery with maintenance of cage height specimens, but the Titanum cage showed no interbody fusion within this period.Radiographic follow-up evaluation showed interbody fusion in 87% of HA/PLLA specimens(7 of 8),as compared with 50% of titanium specimens(2 of 4).During the study period,no local or distant adverse effects were observed.Conclusion HA/PLLA cervical fusion cage is biodegradable,biocompatible material.It is worth further medical research and surgical application in spinal surgery.
出处 《中国骨与关节损伤杂志》 2005年第1期35-37,共3页 Chinese Journal of Bone and Joint Injury
基金 广东省自然科学基金重点攻关课题 课题基金号 :2 0 0 1A30 2 0 2 0 2 0 5
关键词 可吸收颈椎融合器 山羊 动物模型 聚-L-乳酸 羟基磷灰石 复合材料 HA PLLA Spinal fusion Goat cervical fusion model Cage
  • 相关文献

参考文献10

  • 1Verheyen CC, de Wijn JR, van Blitterswijk CA, et al. Evaluation of hydroxyapatite/poly (L- lactide) composites: mechanical behavior. J Biomed Mater Res, 1992, 26:1277
  • 2Furukawa T, Matsusue Y, Yasunaga T, et al. Histomorphometric study on high - strength hydroxyapatite/poly (L - lactide) composite rods for internal fixation of bone fractures. Biomed Mater Res,2000, 5, 50 (3): 410
  • 3Hasegawa Y, Sakano S, Iwase T, et al. The long- term behavior of poly- L-lactide screws in a minipig fracture model: reliminary report. J Biomed Mater Res, 2002, 63 (6): 679
  • 4Moore RJ, Osti OL, Vernon - Roberts B, et al. Changes in endplate vascularity after an outer annulus tear in the sheep, Spine,1992, 17:874
  • 5Wilke HJ, Wenger K, Claes LE. Are sheep spines a valid biomechanical model for human spines? Spine, 1997, 22:2365
  • 6Kandziora F, Pflugmacher R, Scholz M, et al. Comparison between sheep and human cervical spines: an anatomic, radiographic,bone mineral density, and biomechanical study. Spine, 2001,26:1028
  • 7Van Dijk M, Smit T, Sugihara S, et al. The effect of cage stiffness on the rate of lumbar interbody fusion. An in vivo model using PLLAand titanium cages. Spine, 2002, 27:682
  • 8Jeffrey M. Toth, Bradley T. Estes, Mei Wang, et al. Evaluation of 70/30 D, L- PLA for use is a resorbable interbody fusion cage. J Neurosurg, 2002, 97 (4 Suppl): 423
  • 9Burwell RG. The function of bone marrow in the incorporation of a bone graft. Clin Orthop, 1985, 200:125
  • 10胡玉华,石志才,李家顺,贾连顺,侯铁胜.聚醚醚酮复合材料颈椎融合器的临床研究(14例临床初步报告)[J].中国矫形外科杂志,2000,7(11):1052-1055. 被引量:7

二级参考文献4

共引文献6

同被引文献66

引证文献4

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部