期刊文献+

穿透性角膜移植对角膜屈光的影响及其控制

下载PDF
导出
摘要 本文分析了穿透性角膜移植术(PKP)中植片植床制作、缝合方法等操作对术后角膜屈光状态的影响,阐述并比较分析了术后存在屈光不正的各种处理方法,证明术后调整缝线、手术等方法能有效降低PKP后的屈光不正,使患者视力得到更好的矫正与恢复。
作者 郭锐 施明光
出处 《国外医学(眼科学分册)》 2004年第6期366-370,共5页 Foreign Medical Sciences(Section of Ophthalmology )
  • 相关文献

参考文献25

  • 1Sarhan ARS, Dua HS, Beach M. Effect of disagreement between refractive, keratometric, and topographic determination of astigmatic axis on suture removal after penetrating keratoplasty. Br J Ophthalmol, 2000,84:837-841.
  • 2Chang SM, Su CY, Lin CP. Correction of astigmatism after penetrating keratoplasty by relaxing incision with compression suture: a comparison between the guiding effect of photokeratoscope and of computer-assisted videokeratography. Cornea,2003,22: 393-398
  • 3Ramirez M, Hodge DO, Bourne WM. Keratometric results during the first year after keratoplasty: adjustable single running suture technique versus double running suture technique. Ophthalmic Surg Lasers, 2001,32: 370-374.
  • 4Shimmura S, Ohashi Y, Shiroma H,et al. Corneal opacity and cataract: triple procedure versus secondary approach. Cornea, 2003,22: 234-238.
  • 5Seitz B, Langenbucher A, Kuchle M, et al. Impact of graft diameter on corneal power and the regularity of postkeratoplasty astigmatism before and after suture removal. Ophthalmology, 2003, 110: 2162-2167.
  • 6Geggel HS.Technique to minimize asymmetric suture placement during penetrating keratoplasty. Cornea, 2002,21: 17-21.
  • 7Carvalho L,Tonissi SA,Castro JC. Preliminary tests and construction of a computerized quantitative surgical keratometer. J Cataract Refract Surg, 1999,25: 821-826.
  • 8Rudd JC, Weis J, Connors R,et al. Introduction of corneal astigmatism through placement of a scleral fixation ring in eye bank eyes.Cornea,2001,20: 864-865.
  • 9Busin M, Arffa RC. Deep suturing technique for penetrating keratoplasty. Cornea, 2002,21: 680-684.
  • 10Shimazaki J, Shimmura S, Tsubota K. Intraoperative versus postoperative suture adjustment after penetrating keratoplasty. Cornea,1998,17:590-594.

二级参考文献1

  • 1冯葆华,中华眼科杂志,1980年,16卷,14页

共引文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...