摘要
讨论了80C196KC单片机和MCS 51系列单片机之间进行通信时存在的问题,提出利用数字示波器测试数据通信周期的方法调整波特率,从而提高了通信的可靠性.
The problems existed in the communication between single chip computer 80C196KC and MCS-51 series are discussed in this paper. The method regulating the baud rate by oscilloscope to test the period of the data communication and increasing the reliability of the communication are also introduced.
出处
《天津工业大学学报》
CAS
2004年第6期69-70,73,共3页
Journal of Tiangong University
关键词
数字示波器
波特率
通信周期
digital oscilloscope
baud rate
communication period