期刊文献+

供水管网检漏技术现状及发展趋势 被引量:19

Leakage Testing Techniques and Prospect for Ductwork of Water Supply
下载PDF
导出
摘要 我国城市多数供水设施较陈旧、管理体制不健全以及检测技术水平发展不均衡,导致城市供水漏失率在20%~30%,其中约70%是供水管道漏水造成的.简要介绍了供水管网检漏技术在世界上的发展概况和在我国的应用现状;阐述了目前常用的11种检漏技术的原理步骤、仪器设备及其适应性;重点分析了漏水声波检漏法在实际应用中存在的明显不足与产生原因.供水管网检漏技术在我国的发展趋势将由原始、简单、粗糙向现代高、精、尖转变. The avevage rate of water supply leakage in our cities is between 25%~30%,due to the problems of outdated water supply facilities,unamplified management system and the disequilibrium of testing technique development,among which 70% leakege is caused in pipes.The international up-to-date development of testing ductwork fechnique of water supply is introduced togther with the present application in China.A further presentation is put forward about the 11 kinds of testing techniques,their principles,equipment and adaptabitites with an analysis of disadvanteses in the sound-wave testing method.The prospect of testing ductwork techniques in water supply in our country is discussed.There will be a transformation for the present techniques from simple,unexact and primitive to comprensive,precise and modern.
出处 《桂林工学院学报》 2004年第4期456-460,共5页 Journal of Guilin University of Technology
基金 西部开发科技行动项目(2001BA901A09-06)
关键词 供水管网 检漏 信号 地质雷达 ductwork of water supply testing leakage signal geologic radar
  • 相关文献

参考文献14

  • 1徐新旋.相关仪的运用[J].地下管线管理,2001,11(3):47-48.
  • 2蒋峰,范瑾初,李景华.给水管道检漏工作的新发展[J].化工给排水设计,1994(1):39-43. 被引量:8
  • 3徐统涛.浅析漏水管道漏损及检测[J].地下管线管理,2001,(3):53-54.
  • 4[6]常贵林,刘吉东.工业泄漏与治理[M].北京:中国石化出版社,2001.
  • 5刘淑媛.谈地下管网测漏中水平衡探测[J].地下管线管理,1996,(2):54.
  • 6张文智.浅论流量测定在漏水调查中的应用[J].地下管线管理,1997,(1):35.
  • 7陈海生,谢广省.给水管网"升压检漏"法[J].地下管线管理,1999,(1):35-36.
  • 8赵炳海.检测管道泄漏的新方法[J].地下管线管理,1996,.
  • 9孙立国,郝英杰.氢气示踪法在检验新建管道中的应用[J].地下管线管理,2001,(6):53-55.
  • 10王继明,杨昌彬.浅谈漏水听音原理及在实践中的应用[J].地下管线管理,2002,(3):38-39.

二级参考文献7