摘要
通过对主送轨机液压系统的工作原理分析 ,确定了保压不正常的原因 ,并对其改进 ,使液压系统能够达到保压、稳定、持续 ,解决电机系统长期负载运行问题 .
Through work theory analysis of fluid system of primary rail delivery machine, it can certain the cause of abnormal pressure maintenance, and then improve it to assure that fluid system can maintain pressure, stably and continuously, which solves long time run of motor system under load.
出处
《鞍山师范学院学报》
2001年第3期62-65,共4页
Journal of Anshan Normal University
关键词
泄漏
失压
保压系统
leak
Pressure loss
System of pressure maintenance