期刊文献+

建筑物外墙逐时负荷计算及空调节能分析 被引量:11

Building outer wall instantaneous load calculation and air-condition energy economy analysis
下载PDF
导出
摘要 以 3种典型的建筑外墙体结构为例 ,在室外温度周期性非稳态变化的条件下 ,分别对其进行了动态负荷计算。分析了通过不同建筑外墙形成的冷负荷的变化特性 ,结合评价人体舒适性的PMV指标 。 Three typical building outer walls have been taken as cases that were calculated instantaneous load under the condition that the outer air temperature vary unsteadily in periodicity. According to the cold load's change characters made by the different walls and PMV index about body comfortable nature, the outer wall structure and the inside air-condition design parameters' effects on the air-condition energy economy have been given in this paper.
出处 《节能》 2005年第2期38-41,共4页 Energy Conservation
关键词 建筑外墙 建筑物外墙 负荷计算 PMV指标 墙体结构 动态负荷 空调设计 重大 变化特性 周期性 envelop structure air-condition cold load air-condition energy economy body comfortable nature
  • 相关文献

参考文献8

二级参考文献24

  • 1王子介.辐射采暖住宅建筑能耗与室内作用温度[J].南京师范大学学报(工程技术版),2002,2(2):78-83. 被引量:11
  • 2[1]Fanger P O. Thermal Comfort[M]. Malabar: Krieger Publishing Company, 1982.
  • 3[2]American Society of Heating, Refrigeration and Air Conditioning Engineer Inc. ASHRAE Handbook (SI) Fundamental[Z]. 1997.
  • 4[3]American Society of Heating, Refrigeration and Air Conditioning Engineer Inc. ASHRAE Applications Handbook[Z]. 1999.
  • 5郭宽良 孔祥谦 陈善年.计算传热学[M].合肥:中国科技大学出版社,1988.33-49.
  • 6United Nations Environment Network Global Environment Outlook GEO-3[EB/OL].2002,http://www.unep.net/,2002.
  • 7赵正湘.再生资源研究与可持续发展战略[EB/OL].http://www.newenergy.org.cn/expert/mingkan/2002121801.asp,2002.
  • 8庄贵阳.举步维艰的京都议定书[EB/OL].http://www.iwep.org.cn,2003.
  • 9Yeang,Ken.Reinventing the Skyscraper:a vertical theory of urban design[M].Chichester:Wiley-Academy,2002
  • 10Hawkes D,McDonald J,Steemers K.The Selective Environment[M].Spon Press,2002