降低时间分辨力对CT灌注图像的影响 被引量:4

The Quality of CT Perfusion Image of Low Temporal Resolution
下载PDF
导出
摘要 目的:探讨降低时间分辨力对CT灌注成像(CTP)参数图数据测量以及图像质量的影响。方法:对15例急 性脑缺血患者的CTP成像资料进行回顾性分析。分别采用全部数据和按一定时间间隔选择部分数据进行CT灌注图像 的计算,每组数据的时间分辨力分别为0.5s、1s、2s和4s,并在不同时间分辨力的CTP图像上选择相同部位的ROI进行 灌注参数(CBF、CBV、MTT)的测量并对每组数据进行配对t检验。结果:降低时间分辨力在一定范围内(≤2s)对各灌注 参数图的图像质量以及CBV绝对值的测量影响不大,但对参数CBF和MTT的绝对值测量产生显著影响。以健侧大脑 半球作为内参照时,降低时间分辨力不会影响对病变的检出。结论:降低CT灌注扫描的时间分辨力可以在不影响临床 诊断的情况下扩大灌注扫描范围。 Objective:To evaluate the quality of CT perfusion image and data measurement of low temporal resolution.Methods:The CT perfusion data of 15 acute cerebral ischemic patients were investigated retrospectively.The CT perfusion images were calculated by all the data and the partial data,whose corresponding temporal resolution were 0.5s,1s,2s and 4s respectively.The same ROI on the CT perfusion images of different temporal resolution were choosen to evaluate the variability by paired t test.Results:The change of the quality of CT perfusion images and the value of CBV could be omitted when the temporal resolutions were decreased within a certain extent (≤2s),but the values of CBF and MTT changed remarkably following the decrease of the temporal resolution.The detection of the lesions was not influenced in all temporal resolution mentioned above when the contralateral side was regarded as reference.Conclusion:We can enlarge the scan extent of the CT perfusion examination at the cost of the temporal resolution without decreasing the clinical diagnostic capability of CT perfusion scan.
出处 《放射学实践》 2005年第2期114-117,共4页 Radiologic Practice
关键词 时间分辨力 体层摄影术 X线计算机 图像处理 计算机辅助 Temporal resolution Tomography,X-ray computed Image processing,computer assisted
  • 相关文献

参考文献3

  • 1The National Institute of Neurological Disorders and Stroke rt-PA Stroke Study Group. Tissue Plasminogen Activator for Acute Ischemic Stroke[J].N EnglJ Med,1995,333(24):1581-1587.
  • 2Ueda T, Yuh WT, Taoka T. Clinical Application of Perfusion and Diffusion MR Imaging in Acute Ischemic Stroke[J]. J Magn Reson Imaging, 1999,10(3) :305-309.
  • 3Roberts HC, Roberts TP, Smith WS,et al. Multisection Dynamic CT Perfusion for Acute Cerebral Ischemia: the Toggling-Table Technique[J]. AJNR,2001,22(6) : 1077-1080.

同被引文献25

  • 1Guo-Lin Ma,Rong-Jie Bai,Hui-Jie Jiang,Xue-Jia Hao,Xu-Peng Dong,Da-Qing Li,Xin-Ding Liu and Lai Wei Department of Radiology,China-Japan Friendship Hospital,Beijing 100029,China,Department of Radiology,Beijing Jishuitan Hospital,Beijing 100035,China,Department of Radiology,Second Affiliated Hospital,Harbin Medical University,Harbin 150086,China.Early changes of hepatic hemodynamics measured by functional CT perfusion in a rabbit model of liver tumor[J].Hepatobiliary & Pancreatic Diseases International,2012,11(4):407-411. 被引量:8
  • 2袁小东,张静,田建明,陈炜.CT灌注在低注射流率时最大斜率法的准确性分析及改良[J].放射学实践,2005,20(4):345-348. 被引量:5
  • 3吴庆德,胡春洪.基于最大斜率模型脑CT灌注量的改良算法[J].中国医学影像技术,2006,22(12):1907-1910. 被引量:5
  • 4Lovblad KO, Baird AE. Computed tomography in acute ischemic stroke. Neuroradiology, 2010, 52:175-187.
  • 5Wintermark M, Smith WS, Ko NU, et al. Dynamic perfusion CT: optimizing the temporal resolution and contrast volume for calculation of perfusion CT parameters in stroke patients. AJNR, 2004, 25:720-729.
  • 6Wiesmann M, Berg S, Bohner G, et al. Dose reduction in dynamic perfusion CT of the brain: effects of the scan frequency on measurements of cerebral blood flow, cerebral blood volume, and mean transit time. Eur Radiol, 2008, 18:2967-2974.
  • 7Kloska SP, Fischer T, Sauerland C, et al. Increasing sampling interval in cerebral perfusion CT: limitation for the maximum slope model. Acad Radiol, 2010, 17:61-66.
  • 8Abels B, Klotz E, Tomandl BF, et al. CT perfusion in acute ischemic stroke: a comparison of 2-second and 1-second temporal resolution. AJNR, 2011, 32:1632-1639.
  • 9Miles KA, Hayball M, Dixon AK, et al. Colour perfusion imaging: a new application of computed tomography. Lancet, 1991, 337:643-645.
  • 10Prasad SR, Wittram C, Shepard JA, et al. Standard-dose and 50%-reduced-dose chest CT: comparing the effect on image quality. AJR, 2002, 179:461-465.

引证文献4

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部