摘要
建立了悬浮液进样流动注射在线微波消解 冷蒸气原子荧光光谱法测定生物和环境样品中Hg的方 法。样品分散在50%(V/V)王水中,通过磁力搅拌保证样品溶液的均一性与稳定性。方法的检出限为 0.06μg/L。方法简单快速,灵敏度高,样品损失少,而且没有样品交叉污染。应用此方法测定了5种标准参 考物质以及5个实际样品中的Hg含量,并与传统的高压焖罐强酸消解方法进行了比较,两种方法所得结果 一致,标准参考物质的测定值与标准值很好地吻合。
The method of slurry sampling flow injection-microwave digestion with cold vapor generation-atomic fluorescence detection for the determination of mercury in biological and environmental samples is proposed. Samples were dispersed in 50% (V/V) aqua regia and agitated magnetically to obtain well-proportioned and stable sample solutions. The detection limit of the method was 0.06 mu g/L, with the advantage of simple, quick, sensitive, low losing and no cross-contamination. The slurry sampling technique was compared with the conventional high-pressure strong acids digestion method. Good consistent was got with the two methods and the obtained values were in good agreement with the certified values.
出处
《分析化学》
SCIE
EI
CAS
CSCD
北大核心
2005年第2期229-232,共4页
Chinese Journal of Analytical Chemistry
基金
国家重点基础研究计划(973项目)资助课题(No.2003CB415001)