基于简化的扩散模型,以金属分布近似代替电流分布,并用Wagner数作为评定标准,通过在平板电极和旋转圆盘电极上脉冲镀铜实验,详细研究了一次、二次和三次电流分布的影响。
Based on a simplified diffusion model、with the approximation of metal distribution representing current distribution, and Wagner number as an evaluated standard experiments were made with pulse plating copper on plate electrode and rotating disk electrode, and the influence of pulsed current on primary, secondary and tertiary current distribution was investigated in detail in this paper.