期刊文献+

分娩镇痛对婴幼儿神经行为的影响 被引量:3

The effect of delivery analgesia on infantile neurobehavior
下载PDF
导出
摘要 目的探讨产妇使用自控硬膜外麻醉分娩镇痛(PCEA)对婴幼儿神经行为影响。方法随机选择自愿要求分娩镇痛的产妇134例,使用布比卡因加芬太尼进行分娩镇痛作为观察组,与同期未使用分娩镇痛产妇151例作为对照组,观察比较两组产程中胎心率、新生儿Apgar评分、新生儿出生7d、6月龄、12月龄神经行为情况。结果两组比较产程中胎心率CST监测、新生儿Apgar评分、新生儿出生7d、6月龄、12月龄神经行为均无显著性差异(P>005)。结论布比卡因加芬太尼产妇自控硬膜外麻醉用于分娩镇痛安全可靠,对婴幼儿神经行为无不良影响。 Objective:To discuss the effcts of patient's control epidural analgesia on infantile neurobehavior.Methods:134 parturiens underwent delivery analgesia with bupivacaine and fentanvl were selected as observing group and 151 parturiens without delivery analgesia as control group by random sampling. Compared the fetal heart rate momtormg during labor (CST), neonatal Apagar's score, neurobehavior of neonates 7days old, 6 months old and 12 months old of the two groups. Results:There were no significant differences in fetal heart rate monitoring during labor (CST), neonatal Apagar's score, neurobehavior of neonate aged 7days, 6 months and 12 months between the two groups (P>0.05). Conclusion:Patient's control epidm'al analgesia with bupibacame mid fentanvl is safe and reliable, it has no harmfiful effects on mihnt neurobehavior.
出处 《中国妇幼保健》 CAS 北大核心 2005年第2期189-191,共3页 Maternal and Child Health Care of China
基金 广东省卫生厅科研项目(编号-A688)
关键词 分娩镇痛 婴幼儿 神经行为 影响 Delivery analgesia Infant Neurobehavior Effect
  • 相关文献

参考文献7

二级参考文献24

  • 1张国楼,林桂芳.麻醉与儿茶酚胺[J].国外医学(麻醉学与复苏分册),1995,16(4):202-204. 被引量:41
  • 2何孔源,李树人.分娩镇痛法的临床应用与观察[J].中华麻醉学杂志,1989,9(2):102-104. 被引量:121
  • 3盛卓人.实用麻醉学[M].沈阳:辽宁科学技术出版社,1987.234-238.
  • 4鲍秀兰 郭异珍 等.正常新生儿行为测定[J].中华儿科杂志,1986,24(6):341-341.
  • 5莫惠飞 等.低浓度罗哌卡因和布比卡因用于硬膜外自控分娩镇痛的[J].临床研究世界医药学杂志,2002,2(9):8-10.
  • 6盛卓人主编.实用麻醉学[M].沈阳:辽宁科学技术出版社,1987.466.
  • 7Robertson D, Michelakis AM. Effects of anaesthesia and surgery on plasma rennin activity in man. JCESM, 1972, 34(5) :831-833.
  • 8Eddleston JM, Holland JJ, Griffin RP, et al. A double-blind comparison of 0.25% ropivacaine and 0.25% bupivacaine for extra dural analgesia in labor. Br J Anaesth,1996,76(1):66-71.
  • 9Meister GC, D'Angelo R, Owen MD,et al. A comparison d epidural analgesia with 0.125% ropivacaine with fentanyl versus 0.125% bupivacaine with fentanvl during labor. Anesth Analg,2000,90(5) :632 - 637.
  • 10Fischer C, Blanie P, Jaouen E, et al. Ropivacaine 0.1% plus sufentanil 0.5 mg/mL versus bupivacaine 0.1% plus sufentanil 0.5mg/mL using patients-controlled epidtnal analgesia for labor. Anesthesiology,2000,92(4) : 1588 -1593.

共引文献35

同被引文献21

引证文献3

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部