摘要 农药残留物对人类健康危害极大,农业和环境中农药检测非常重要。该文综述各类生物传感器在农药检测研究中的应用进展。 Rudimental of pesticides in the environment is dangerous for human. Detection of pesticides is very important in the agriculture and environment. Progress on the studies and application of the various biosensors in the determination of pesticides are reviewed.
作者 文茜 黄杉生
出处 《化学传感器》 CAS 2004年第4期1-6,共6页 Chemical Sensors
关键词 农药检测 生物传感器 农药残留 酶阻法 biosensor agriculture pesticide rudimental detection
  • 相关文献

参考文献54

  • 1Smith R K. Handbook of environmental analysis[M] .3rd Edition, NY: Genium Publishing Corporation,Schenectady, 1997.
  • 2Csuros M. Environmental sampling and analysis for technicians[M]. MI: Lewis Publishers, Chelsea, 1994.
  • 3Keith L H. Environmental sampling and analysis: A practical guide [M] . MI: Lewis Publishers, Chelsea,1992.
  • 4李元光,罗毅,蒋中华,马立人.生物传感器在有机磷农药及神经性毒剂检测中的应用[J].化学传感器,1997,17(3):161-170. 被引量:7
  • 5Clark L C, Lyons C. Electrode systems for continuous monitoring cardiovascular surgery [J]. Ann. N. Y. Acad.Sci., 1962, 102:29 - 45.
  • 6Updike S J, Hicks G P. The enzyme electrode[J]. Nature, 1967, 214:986-988.
  • 7Cass A E G, Kavis G, Francis G D, et al. Ferrocene mediated enzyme electrode for amperometric determination of glucose[J]. Anal. Chem., 1984,56:667-671.
  • 8Takakusa H, Kikuchi K, Urano Y, et al. Design and synthesis of an enzyme cleavable sensor molecule for phosphodiesterase activity based on fluorescence resonance energy transfer[J]. J. Am. Chem. Soc.,2002,124:1653-1657.
  • 9Mitchell K M. Acetyleholine and choline ampemmetrie enzyme sensors characterized in vitro and in vivo[J] .Anal. Chem., 2004, 76:1098-1106.
  • 10Gorton L, Lindgrren A, Larsson T, et al. Direct electron tmsfer between heme-containing, enzymes and electrode as basis for third generation biasensors[J] .Anal. Chim. Acta, 1999,400:91-108.

二级参考文献4

  • 1Chuanming Duan,Mark E. Meyerhoff. Immobilization of proteins on gold coated porous membranes via an activated self-assembled monolayer of thioctic acid[J] 1995,Mikrochimica Acta(3-4):195~206
  • 2U. L?ffler,U. Wollenberger,F. Scheller,W. G?pel. Amperometrische Biosensoren zur Bestimmung von Cholin und Acetylcholin[J] 1989,Fresenius’ Zeitschrift für Analytische Chemie(3):295~298
  • 3Georg Schwedt,Michael Hauck. Reaktivierbare Enzymelektrode mit Acetylcholinesterase zur differenzierten Erfassung von Insecticiden im Spurenbereich[J] 1988,Fresenius’ Zeitschrift für Analytische Chemie(3-4):316~320
  • 4王道,桑鸿勋.化学传感器[J].化学教育,1989,4(3):4-6. 被引量:6

共引文献6

同被引文献10

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部