The dielectric barrier corona discharge(DBCD) in a wire-cylinder configuration and the dielectric barrier discharge(DBD) in a coaxial cylinder configuration are studied. The discharge current in DBD has a higher pulse amplitude than in DBCD. The dissipated power and the gas-gap voltage are calculated by analyzing the measured Lissajous figure. With the increasing applied voltage, the energy utilization factor for SO2 removal increases in DBCD but decreases in DBD because of the difference in their electric field distribution. Experiments of SO2 removal show that in the absence of NH3 the energy utilization factor can reach 31 g/kWh in DBCD and 39 g/kWh in DBD.
The dielectric barrier corona discharge(DBCD) in a wire-cylinder configuration and the dielectric barrier discharge(DBD) in a coaxial cylinder configuration are studied. The discharge current in DBD has a higher pulse amplitude than in DBCD. The dissipated power and the gas-gap voltage are calculated by analyzing the measured Lissajous figure. With the increasing applied voltage, the energy utilization factor for SO2 removal increases in DBCD but decreases in DBD because of the difference in their electric field distribution. Experiments of SO2 removal show that in the absence of NH3 the energy utilization factor can reach 31 g/kWh in DBCD and 39 g/kWh in DBD.