摘要
本文介绍了本实验室建立的防护级γ射线参考辐射场 ,并对辐射场进行了测定和评价。对距源 1m处空气比释动能率测量 ,结果表明 :1 8.5GBq的137Cs源参考辐射场的空气比释动能率的不确定度为 4.6% ,74GBq的137Cs源参考辐射场的空气比释动能率的不确定度为 4.6% ,3 7GBq的6 0 Co源参考辐射场的空气比释动能率的不确定度为 4.2 %。同时也对辐射场大小和均匀性进行测量。这些结果表明散射辐射、辐射场的均匀性均符合ISO 40 3
This paper describes establish and of γ reference radiation fields with radiation protection level and its determination and evaluation. The Air Kerma Rate which is 1 meter from the source was measured.The results show that uncertainties of Air Kerma Rate are less than 4.6% for 137Cs(18.5?GBq),4.6% for 137Cs(74?GBq),4 2% for 60Co(37?GBq).The size of radiation field and its uniformity were also measured. These results show that scattering radiation and uniformity of radiation field accord with the ISO 4037.
出处
《辐射防护》
CAS
CSCD
北大核心
2005年第1期51-55,共5页
Radiation Protection