期刊文献+

Methodological Studies on Plasma Endotoxin Level and Endotoxin Inactivation Capacity

Methodological Studies on Plasma Endotoxin Level and Endotoxin Inactivation Capacity
下载PDF
导出
摘要 Summary: To establish stable methods for detecting plasma endotoxin level and endotoxin inactivation capacity in a normal population and general surgical patients and evaluate their perioperative changes, 50 healthy people and 50 patients receiving gastrointestinal operation were enrolled, their plasma endotoxin levels and plasma endotoxin inactivation capacity were assayed. Our results showed that plasma endotoxin levels were 0.044±0.009 EU/ml in the normal population and 0.044±0.023 EU/ml in the preoperative patients. Endotoxin level peaked 3 h after the operation (0.223±0.041 EU/ml), and then decreased rapidly on the first day after the operation (0.134±0.164 EU/ml). Endotoxin inactivation capacity also had the same time course as endotoxin level. Systemic inflammatory response syndrome and infection induced another elevation in the time course. It is concluded that establishing the endotoxin standard curve by using pyrogenic free water is better than by using plasma. Plasma endotoxin inactivation capacity can be used as an indirect indicator of postoperative immune depression. Plasma endotoxin level and endotoxin inactivation capacity peaked shortly after operation, indicating surgical stress is closely related with the changes. Summary: To establish stable methods for detecting plasma endotoxin level and endotoxin inactivation capacity in a normal population and general surgical patients and evaluate their perioperative changes, 50 healthy people and 50 patients receiving gastrointestinal operation were enrolled, their plasma endotoxin levels and plasma endotoxin inactivation capacity were assayed. Our results showed that plasma endotoxin levels were 0.044±0.009 EU/ml in the normal population and 0.044±0.023 EU/ml in the preoperative patients. Endotoxin level peaked 3 h after the operation (0.223±0.041 EU/ml), and then decreased rapidly on the first day after the operation (0.134±0.164 EU/ml). Endotoxin inactivation capacity also had the same time course as endotoxin level. Systemic inflammatory response syndrome and infection induced another elevation in the time course. It is concluded that establishing the endotoxin standard curve by using pyrogenic free water is better than by using plasma. Plasma endotoxin inactivation capacity can be used as an indirect indicator of postoperative immune depression. Plasma endotoxin level and endotoxin inactivation capacity peaked shortly after operation, indicating surgical stress is closely related with the changes.
出处 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2004年第6期581-584,共4页 华中科技大学学报(医学英德文版)
关键词 ENDOTOXIN endotoxin inactivation capacity endotoxin endotoxin inactivation capacity
  • 相关文献

参考文献1

二级参考文献4

  • 1张志根.外科疾患与内毒素血症研究近况(综述)[J].浙江医科大学学报,1994,23(1):45-48. 被引量:4
  • 2王绍明.定量检测微量内毒素技术探讨[J].上海医学检验杂志,1989,4(3):152-154.
  • 3张志根,浙江医科大学学报,1994年,23卷,45页
  • 4王绍明,上海临床检验杂志,1989年,4卷,152页

共引文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部