摘要
采用Fenton氧化法对含有高浓度COD的冷凝水进行了试验研究.结果表明,在[H2O2]/[Fe2+]=3.6:1、温度为30℃、 3.0的条件下,COD pH的去除率为 65%;在加入紫外光照射的情况下,冷凝液的 COD 去除率可提高到 77%.
Condensed water containing COD of high concentration was analyzed experimentally adopting Fenton oxidation technique. COD removal rate was 65% under the condition of [H2O2]/[Fe2+] = 3.6:l, 30°C and pH 3.0. The COD removal rate would enhance to 77% under the condition of UV eradication.
出处
《中国环境科学》
EI
CAS
CSCD
北大核心
2005年第1期84-87,共4页
China Environmental Science