摘要
论述了黄台发电厂 5号、6号机组节能供热改造技术的不同,由试验测量了机组改造后的经济指标,综述了机组改造投资、效果、工期与经济指标的差别。
The article analyses the difference of technology for energy saving and heat supply retrofit between No.5 and No.6 units installed in Huangtai power plant. The economic characteristic has been measured by performance test after retrofit. The article also expounded the difference of investment,effect,time limit and economic characteristic of reform between two units.
出处
《汽轮机技术》
北大核心
2005年第1期55-58,共4页
Turbine Technology
关键词
100MW机组
节能改造
性能试验
经济指标
MW turbine generator
energy saving retrofit
performance test
economic characteristic