期刊文献+

轴流式心脏辅助装置及其发展现状 被引量:5

下载PDF
导出
摘要 心脏移植术中心脏供体的供需矛盾很突出 ,解决这个问题的主要手段是采用心室辅助装置做移植桥梁过渡。现在国际上应用最广的心室辅助装置是轴流式心室辅助装置 ,本文主要介绍目前国际上应用于临床的轴流式心脏辅助装置的临床效果和处于开发阶段的轴流式心脏辅助装置的实验结果。
作者 吴广辉
出处 《北京生物医学工程》 2004年第4期306-308,共3页 Beijing Biomedical Engineering
基金 北京市自然科学基金项目 (3 0 42 0 0 8)资助
  • 相关文献

参考文献22

  • 1Dennis C,Hall DP,Senning A.Reduction of the oxygen utilization of the heart by left heart bypass.Circ Res,1962;10:298-306
  • 2Nose Y,Schamaun M ,Kantrowitz A .Experimental use of an electrically controlled prosthesis as an auxiliary left ventricular.Trans Am Soc Artif Intern Organs, 1979;9:267-74
  • 3BartMeyns,PaulSergeant.Bridging procedures to heart transplantation.World J Surj,2002,26:212-17
  • 4Meyns B,Sergeant P,Wonters P,et.Mechanical support with microaxial blood pumps for postcardiotomy left ventricular failure:can outcome be predicated? J Thorac Cardiovasc Surg,2000,120:393-400
  • 5Agati S,Bruschi G.Frist successful Italian clinical experience with DeBakey VAD.J Heart Lung Transplant,2001,20:914-17
  • 6Methodist Health Care System:The Methodist Hospital and Baylor College of Medicine Surgeons implant first US patient with DeBakeyVAD.Available at:http://www.Metho- disthealth.com/vad/.June 22,2002
  • 7Availableat:http://www.MicroMedtech.com/productprofile.htm/.June 23,2002
  • 8http://fsnews.findlaw.com/articles/prnewswire/20040327/27mar2004220039.html
  • 9Frazier OH,Timothy J.Research and development of an implantable,Axial-flow left ventricular assist device:the Jarvik 2000 heart.Ann Thoarc Surg,2001,71:125-32
  • 10Saito S,Westaby S.Permanent mechanical circulation support:now a realistic prospect,in program and abstracts of the 10th Congress of the International Society for Rotary Blood Pumps.Osaka,Japan.September 12,2002

同被引文献40

  • 1王守力,韩雅玲,荆全民,王祖禄,王冬梅,邓捷,杨桂棠,于海波.床旁主动脉内球囊反搏术在急性冠脉综合征并发心源性休克救治中的应用[J].第四军医大学学报,2005,26(9):831-833. 被引量:17
  • 2徐晓佳,李帆.轴流式血泵的研究进展[J].北京生物医学工程,2005,24(5):394-397. 被引量:4
  • 3范慧敏,卢容,刘中民.国产植入型心室辅助装置的实验研究[J].同济大学学报(医学版),2006,27(5):6-9. 被引量:6
  • 4Timms D. A review of clinical ventricular assist devices [ J ]. Med Eng Phys, 2011, 33(9) : 1041 -1047.
  • 5Rogers JG, Butler J, Lansman SL, et al. Chronic mechanical circulatory support for inotrope-dependent heart failure patients who are not trans-plant candidates: results of the INTREPID trial [J]. J Am Coil Cardiol, 2007, 50:741 -747.
  • 6Nguycn DQ, Thourani VH. Third-generation continuous flow left ventricular assist devices [ J]. Innovations (Phila), 2010, 5 (4) : 250 -258.
  • 7Patel SM, Throekmorton AL, Untaroiu A, et al. The status of failure and reliability testing of artificial blood pumps [ J ]. ASAIO J, 2005, 51(4) : 440 -451.
  • 8Farrar D J, Bourque K, Dague CP, et al. Design features, developmental status, and experimental results with the Heartmate III centrifugal left ventricular assist system with a magnetically levitated rotor [ J ]. ASAIO J, 2007, 53 ( 3 ) : 310 315.
  • 9Wieselthaler GM, O Driscoll G, Jansz P, et al. Initial experience with a novel left ventricular assist device magnetically levitated rotor in a multi-institutional trial Heart Lung Transplant, 2010, 29 ( 11 ) : 1218 - 1225. clinical with a.
  • 10Morshuis M, Schoenbrodt M, Nojiri C, et al. DuraHeart magnetically levitated centrifugal left ventricular assist system for advanced heart failure patients [ J]. Expert Rev Med Devices, 2010, 7(2) : 173 -183.

引证文献5

二级引证文献27

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部