期刊文献+

混凝土中钢筋宏电池腐蚀电流的研究 被引量:10

Study on Macro Cell Corrosion Current of Steel Bar in Concrete
下载PDF
导出
摘要 在含氯盐混凝土中用零电阻电流计测定了钢筋宏电池阴、阳极之间的腐蚀电流,结果发现腐蚀电流与混凝土中钢筋的腐蚀程度有一定的相关关系,因此,对钢筋宏电池腐蚀电流的测定能够被用来简便地评价混凝土中钢筋宏电池腐蚀程度. Corrosion current between anode steel and cathode stainless steel embedded in chloride contaminated concrete were measured by zero ohm ammeter. This study indicates that there is a proportional expression between corrosion current and lost mass by corrosion of the steel. The results above show that corrosion current measured by ampere meter reflects the macro cell corrosion extent of steel bar in concrete.
出处 《建筑材料学报》 EI CAS CSCD 2005年第1期90-93,共4页 Journal of Building Materials
基金 国家留学基金委资助项目 黑龙江省科技攻关项目(GZ04A612)
关键词 腐蚀电流 钢筋 混凝土 氯盐 阳极 电池 零电阻 电流计 macro cell corrosion calcium nitrite corrosion current lost mass rate
  • 相关文献

参考文献6

二级参考文献4

  • 1.GBJ119—2001.混凝土外加剂应用技术规范(中华人民共和国国家标准)[S].,2001..
  • 2C.L.Page,K.W.J.Treadaway:Aspects of the electrochemistry of steel in concrete,Nature,Vo.297,1982,PP.109—114.
  • 3A.M.ROSENBERG and J.M.GAIDIS:The mechanism of nitrite inhibition of chloride attack on reinforcing steel in alkaline aqueous environments,Materials performance 1979,November,45—48.
  • 4J.A.Gonzalez.E.Ramirez,and A.Bautista:Protection of steel embedded in chloride containing concrete by means of inhibitors,Cement and concrete research,Vo.28,No.4,1998,pp.578.

共引文献16

同被引文献132

引证文献10

二级引证文献116

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部