期刊文献+

下颌升支矢状截骨后不同固定方法稳定性的体外模型研究 被引量:2

The Stability of Various Fixation Patern in Bilaterial Sagittal Split Ramus Osteotomy: a Modeling Study in Vitro
下载PDF
导出
摘要 目的 :比较下颌升支矢状截骨术 (bilateralsagittalsplitramusosteotomy ,BSSRO)后 3种固定方式产生的近远心骨段的稳定性。方法 :选牙列完整的成人下颌骨标本 9件 ,经标准术式的矢状截骨后 ,分别依次行双股钢丝结扎 (wirefixation ,WF)和两种形式的坚固内固定 (rigidinternalfixation ,RIF) :小夹板固定和双皮质螺钉固定。将试件两侧近心段妥善固定后 ,于两侧前磨牙区加载 ,记录不同载荷下远心骨段前端二维方向上的位移量。结果 :1)钢丝结扎后远心骨段在二维方向上的位移大于其它两组 ;2 )随载荷增加 ,远心骨段的位移增大 ;当载荷大于 2 0N时 ,钢丝固定组产生的位移明显大于其它两组 (P <0 .0 5 ) ;3)小夹板固定与双皮质螺钉固定组在二维方向上的位移情况相近 (P >0 .0 5 )。结论 :钢丝固定的稳定性最差 ,双皮质螺钉与小夹板固定的稳定性相似 ,但加载后远心骨段仍有不同程度的移位 ,提示术后应配合暂时性的颌间固定。 Objective: To compare the mandibular stability of the two fragments after BSSRO. Methods: Taking 9 human mandibles without missing teeth, after standard BSSRO procedure, secure the two fragments with wire、mini-plate、and bicortical screw accordingly. Fasten condyles carefully, then applying different loads on pre-molar regions and writing down the movement of distal fragement. Results: 1) The distal fragment's movement of wire fixation group in two directions is bigger than that of the other groups; 2) With increasing load, the distal fragment's movement increase; When the load is larger than 20N, the distal fragement's movement of wire fixation group is obviously longer than that of the other groups(P<0.05); 3)The fragement stability in mini-plate and bicortical screw group is similar(P>0.05). Conclusion: Fragements stability is unfavorable in wire fixation group. Mini-plate and bicortical screw group has a similar stability, but still some different degree movements are found when load is applied, and this suggest a transient maxillo-mandibular fixation is necessary after BSSRO.
出处 《口腔医学研究》 CAS CSCD 2004年第6期628-630,共3页 Journal of Oral Science Research
  • 相关文献

参考文献8

  • 1胡昇,王宏田,丰景.坚固内固定术治疗下颌骨骨折的临床疗效研究[J].口腔医学研究,2004,20(1):84-85. 被引量:2
  • 2Blomqvist JE, Ahlborg G, Isaksson S, et al: A Comparison of Skeletal Stability After Mandibular Advancement and Use of Two Rigid Internal Fixation Techiques. J Oral Maxillofac Surg, 1997,55:568-574
  • 3刘春丽,朴正国,吴安平,吴宏,刘磊.下颌骨骨折钛小夹板固定骨折线稳定性体外模型研究[J].口腔医学研究,2002,18(4):262-264. 被引量:9
  • 4张益,张陈平.颌骨外科与AO内固定新进展(讲座二)——颌骨骨折治疗[J].口腔颌面外科杂志,2000,10(1):41-43. 被引量:53
  • 5Schwartz HC,Robert J.Relle,et al. Bicortical-Monocortical Fixation of the Sagittal Mandibular Osteotomy. J Oral Maxillofac Surg,1996,54:234-235
  • 6Welch TB. Stability in the correction of dentofacial deformities: A comprehensive review. J Oral Maxillofac Surg, 1989, 47(11):1142
  • 7Moenning JE, Bussard DA, Lapp Th, et al. Comparision of relapse in bilateral sagittal splitosteotomies for mandibular advancement: Rigid internal fixation(screws)versus inferior border wiring with anterior skeletal fixation. Int J Adult Orthodon Orthognath Surg, 1990,5(3):175
  • 8张震康, 张熙恩, 傅民魁主编.正颌外科学.北京:人民卫生出版社,1994,184

二级参考文献8

  • 1Champy M,Lodde JP,Jeager JH,et al.Osteosyntheses mandibulaires selon la technique de Michelet.Ⅰ.Bases Biomechaniques.Rev Stomat,1976,77∶569-576
  • 2Michelet FX,Deymes J,Dessus B:Osteosynthesis with miniaturized screwed plates in maxillofacial surgery.J Maxillofac Surg,1973,1∶79-84
  • 3Ellis E,Walker LR.Treatment of mandibular angle fractures using one non-compression miniplate.J Oral Maxillofac Surg,1996,54∶864-871
  • 4Champy M,Pape HD,Gerlach JH,et al.Mandibular fractures.In:Kruger E,Schilli W,Worthington P,eds:Oral and Maxillofacial Traumatology,Vol.2.Chicago:Quintessence,1986,19-43
  • 5Kroon FHM,Mathisson M,Cordey JR,et al.The use of miniplates in mandibular fractures.J Craniomaxillofac Surg,1991,19∶199-204
  • 6Speissl B:Internal Fixation of the Mandible:A Manual of AO/ASIF Principles.New York:Springer-Verlag,1989
  • 7Choi BH,Yoo JH,Kim KN,et al.Stability testing of a two miniplate fixation technique for mandibular angle fractures.An in vitro study.J Craniomaxillofac Surg,1995,23∶122-125
  • 8Tams J,Van Loon JP,Otten E,et al.A three-dimensional study of bending and torsion moments for different fracture sites in the mandible:an in vitro study.J Oral Maxillofac Surg,1997,26∶383-388

共引文献61

同被引文献12

  • 1Wolford LM.The sagittal split ramus osteotomy as the preferred treatment for mandibular prognathism[J].J Oral Maxillofac Surg.2000,58:310-312.
  • 2Ghali GE,Sikes JW Jr.Intraoral vertical ramus osteotomy as the preferred treatment for mandibular prognathism[J].J Oral Maxillofac Surg,2000,58:313 -315.
  • 3Acebal-Bianco F,Vuylsteke PL,Mommaerts MY,et al.Perioperative complications in corrective facial orthopedic surgery:a 5 -year retrospective study[J].J Oral Maxillofac Surg,2000,58:754-760.
  • 4Van de Perre JP,Stoelinga PJ,Blijdorp PA,et al.Perioperative morbidity in maxillofacial orthopedic surgery:a retrospective study[J].J Craniomaxillofac Surg,1996,24:263 -270.
  • 5Westermark A,Bystedt H,von Konow L.Inferior alveolar nerve function after sagittal split osteotomy of the mandible:correlation with degree of intraoperative nerve encounter and other variables in 496 operations[J].Br J Oral Maxillofac Surg,1998,36:429-433.
  • 6Pratt CA,Tippett H,Barnard JD,et al.Labial sensory function following sagittal split osteotomy[ J ].Br J Oral Maxillofac Surg,1996,34:75-81.
  • 7Panula K,Finne K,Oikarinen K.Incidence of complications and problems related to orthognathic surgery:a review of 655 patients[J].Oral Maxillofac Surg:2001,59(10):1128-1136.
  • 8Maurer P,Knoll W D,Schubert J.Comparative evaluation of two osteosynthesis methods on stability following sagittal split ramus osteotomy[J]. Craniomaxillofac Surg,2003,31(5):284-289.
  • 9Beck M,Koolstra JH,Van Ruijven LJ,et al.Three-dimensional finite element analysis of the human temporomandibular joint disc[J].Biomech,2000,33(3):307-316.
  • 10Fernandez JR,Gallas M,Burguera M,et al.A threedimensional numerical simulation of mandible fracture reduction with screwed miniplates[J].Biomech,2003,36(3):329-337.

引证文献2

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部