摘要 微型轴流式血泵是目前人工心脏结构研究的热点,外磁驱动是一种新型的血泵驱动方式。本文介绍了血泵外磁驱动电路的设计。该电路能够产生双向励磁电流,直接驱动电机,实现血泵的外磁驱动。电路简单、实用,稳定性较好。 Minisize axial flow blood pump is the focus on the structure study of artificial heart recently. Being driven via outside magnetic field is a new driving method on blood pump. In the article, the design of outside magnetic driving circuit of blood pump is introduced. The circuit can create bi-directional current, which can directly drive the motor. Therefore to be driven via outside magnetic field is realized. The circuit is simple, practical and stable.
机构地区 中南大学
出处 《微计算机信息》 北大核心 2005年第2期88-89,共2页 Control & Automation
基金 国家自然基金(编号:E050105) 湖南自然科学基金(编号:02JJY2080)
关键词 轴流式血泵 磁场 双向电流 功率放大器 axial flow blood pump magnetic field Bi-directional Current power amplifier
  • 相关文献

参考文献1

  • 1Li G R, Ma W G, Zhu X D, et al. Preliminary study on an introaortic pump driven by a distant rotary magnet[J]. ASAIO Journal,2000,46:151.

同被引文献25

  • 1高双印,耿少毅.单片机励磁调节器的应用[J].黑龙江水利科技,2004,32(1):105-106. 被引量:2
  • 2陈建伟,龚忠良,谭建平,陈新.基于单片机控制的微型轴流式血泵外磁驱动系统[J].机电一体化,2004,10(6):33-36. 被引量:3
  • 3龚中良,谭建平,李国荣.基于血泵驱动外磁场产生方法的研究[J].生物医学工程研究,2004,23(4):201-203. 被引量:3
  • 4徐先懂,谭建平,龙东平.轴流式血泵驱动系统研究[J].中国医学工程,2006,14(1):1-3. 被引量:5
  • 5姚泰主编.生理学[M].第6版.北京.人民卫生出版社,2003.326.
  • 6William L H, Salpy V P, Margaret B, et al. Managing device infections: are we progressing or is infection an insurmountable obstacle? [ M ]. ASAIO Journal, 2005. 452 - 455.
  • 7Julie A S, Ma R. Implantable left ventricular assist devices[J].Journal of cardiovascular nursing, 2005,20( 55 ) :522 - 530.
  • 8Ayre P J, Vidakovi S S, Tansley G D,et al. Sensorless flow and head estimation in the ventrassist rotary blood pump [ J ]. Artif Organs. 2000,24(8) :585 - 588.
  • 9Makoto Y, Tsutomu S,Akira T,et al. Sensorless estimation of pressure head and flow of a continuous flow artificial hear based on input power and rotational speed [ M ]. ASAIO Journal. 2000.443 - 448
  • 10Yin C Y, Robert B J, Marwan A, et al. Minimally invasive estimation of systemic vascular parameters for artificial hear control [ J ]. Control engineering pactice, 2000 (10) :277 - 285.

引证文献4

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部