期刊文献+

Φ12.7mm测试电容传声器灵敏度的一种简易校准方法

A Simple Method for Calibrating the Sensitivity of Φ12.7 mm Condenser Microphone
下载PDF
导出
摘要 没有专门的校准设备通常难以进行测试传声器灵敏度校准,这个因素限制了传声器的日常校准。充分使用实验室现有的设备,提出一种Φ12.7mm测试电容传声器灵敏度的简易校准方法,几乎具有专门校准设备的校准精度。 Generally,it is difficult to calibrate microphone sensitivity without special calibration instruments, which makes the maintenance of microphone can't be done frequently. A simple method that uses the common instruments in the laboratory to calibrate microphone sensitivity is presented. Furthermore, the calibration precision of this method is almost as good as that of the professional calibration instruments.
出处 《电声技术》 2005年第1期62-64,共3页 Audio Engineering
基金 国防预研基金支持项目(41307010106).
关键词 传声器 灵敏度 校准 microphone sensitivity calibration
  • 相关文献

参考文献4

二级参考文献6

  • 1刘万年.怎样正确选择和使用传声器[J].中国医学教育技术,1991,9(2):106-109. 被引量:2
  • 2[1]International Standard.IEC 327 Precision Method for Pressure Calibration of One-inch Standard Condenser Microphones by the Reciprocity Technique[S].Switzerland:International Electrotechnical Commission,1971.
  • 3[2]International Standard.IEC 60318 Electroacoustics-Simulator of human head and ear[S].Switzerland:International Electrotechnical Commission,1998.
  • 4[3]Deutsche Norm.DIN 1319-3,Grundlagen der Messtechnik, Teil 3: Auswertung von Messungen einer einzelnen Messgroesse Messunsicherheit[M].Berlin:Deutsches Institut fuer Normung,1996.
  • 5[4]Jarvis D R.The accuracy of the electrostatic actuator method of determining the frequency response of condenser microphones[J].Journal of Sound and Vibration.1988,123(1),63-70.
  • 6许作民等编著.《电视节目制作手册》.中国广播电视出版社,1991