期刊文献+

易破裂斑块的血管内检测 被引量:1

下载PDF
导出
摘要 研究发现引起急性冠脉综合征的常见"罪犯"斑块具有特殊形态特征,不但容易破裂, 继发血栓形成阻塞管腔,而且常规冠脉造影难以检出。鉴于其危害性,众多学者致力于采用新型血管内检测方法检出这种易破裂斑块。本文对相关的血管内检测方法作一综述。
作者 鲁静朝 崔炜
出处 《国外医学(心血管疾病分册)》 2005年第1期28-31,共4页
  • 相关文献

参考文献25

  • 1Takano M, Mizuno K, Yokoyama S, et al. J Am Coll Cardiol,2003 ;42(4): 680~686.
  • 2Kotani J,Mintz GS, Castagna MT,et al. Circulation,2003;107(23) :2 889~2 893.
  • 3Saijo Y,Tanaka A,Owada N,et al. Ultrasonics,2004;42(1-9) :753~757.
  • 4Pasterkamp G,Falk E,Woutman H,et al. J Am Coll Cardiol,2000;36(1): 13~21.
  • 5de Korte CL, Sierevogel MJ, Mastik F, et al. Circulation,2002; 105 (14): 1627~ 1630.
  • 6Schaar JA, De Korte CL, Mastik F, et al. Circulation, 2003 ;108(21) :2 636~2 641.
  • 7Schaar JA, Regar E, Mastik F, et al. Circulation, 2004; 109(22) :2 716~2 719.
  • 8Patwari P,Weissman NJ,Boppart SA, et al. Am J Cardiol,2000;85(5) :641~644.
  • 9Jang IK, Bouma BE, Kang DH, et al. J Am Coll Cardiol,2002 ;39(4) :604~609.
  • 10Yabushita H,Bouma BE, Houser SL, et al. Circulation, 2002 ;106(13) : 1 640~1 645.

同被引文献12

  • 1Rubin G D, Dake M D, Senba C P. Current status of threedimensional spiral CT scanning for imaging the vascularture[J].Radiol Clin North Am,1995,33(1):51
  • 2Schroeder S,Kopp A F,Baumbach A,et al. Noninvasive detection and evaluation of atherosclerotic coronary plaques with multislice computed tomography[J]. J Am Coll Cardio,2001,37(5):1430
  • 3Achenbach S, Giesler T, Ropes D, et al. Detection of coronary artery stenosis by contrast-enhanced, retrospecticely elect rocardiographically-gated, multislice spiral computed tomography[J]. Circulation, 2001,103 (20):2535
  • 4Briguori C, Anzuini A, Airoldi F, et al. Intravascular ultrasound criteria for the assessment of the functional significane of intermediate coronary artery stenoses and comparison with fractional flow reserve [J]. Am J Cardiol, 2001,87 (2) : 136
  • 5Kobayashi Y, Honda Y, Christie G L, et al. Long-term vessel response to a self-expanding coronary stent: a sertalvolumetric in-travascular ultrasound analysis from the ASSURE Trial. A Stent vs. Stent Ultrasound Remodeling Evaluation[J]. J Am Coll Cardiol, 2001,37(5) : 1329
  • 6Schiele F , Meneveau N , Gilard M , et al. Intravascular ultrasound guided balloon angioplasty compared with stent:immediate and 6-month results of the multicenter, randomized Balloon Equivalent to Stent Study (BEST) [J]. Circulation,2003,107(4) :545
  • 7Yock P G,Fitzgerald P J. Intravascular ultrasound:state of the art and futrure directions [J]. Am J Cardiol, 1998,81 (TA) : 27E
  • 8Grube E, Gerekens U, Buellesfeld L, et al. Images in cardiovascular medicine. Intracoronary imaging with optical coherence tomography. A new high-resolution technology providing striking visualization in the coronary artery[J].Circulation, 2002., 106 (18):2409
  • 9Brezinski M E, Tearney G J, Bouma B E, et al. Imaging of coronary artery microstructure (in vitro)with optical coherence tomography [J]. Am J Cardiol, 1996,77 (1) : 92
  • 10DEBATE study group. Are flow velocity measurements after PTCA predictive of recunence of angina or of a positive exercise test early after balloon angioplasty (abstract)[J]. Circulation,1995,92(3):264

引证文献1

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部