摘要
介绍410t/hCFB锅炉选择性排灰冷渣器调试过程中应该注意的一些问题,并提出预防冷渣器堵渣和处理堵渣的方法,为同类型冷渣器的调试提供建议。
This paper discusses some notable problems during commissioning of selective slag cooler of 410 t/h CFB boiler, and provides methods to prevent and treat the slag block of the cooler, as a suggestion for regulating and testing the same type coolers.