期刊文献+

温泉宾馆室内PM_(10),PM_(2.5),CO_2和^(222)Rn的研究 被引量:9

Studies on PM_(10),PM_(2.5),CO_2 and ^(222)Rn in the hot spring hotel rooms
下载PDF
导出
摘要 对广东省 4座温泉宾馆室内外氡(222Rn)浓度和温泉水氡浓度进行研究,同时利用便携式探测器对室内外 PM10,PM2.5,CO2和CO 等污染物暴露水平进行直接测定.结果表明,温泉宾馆室内使用温泉水时氡浓度明显高于广东省室内平均氡浓度.除 CO 外,室内 PM10,PM2.5 和CO2 浓度都较高,其中 PM10 和 CO2 的超标率分别达到 67%和 89%.说明温泉宾馆室内不仅存在一般性污染物,而且存在高浓度的 Rn. Radon (222Rn) concentrations in indoor and outdoor air, as well as in hot spring waters, were studied in four hot spring hotels in Guangdong province; meanwhile PM10, PM2.5, CO2and CO pollutants exposure levels were determined directly with portable detector. Radon concentration in the hot spring hotel rooms at use of hot spring was higher markedly than the average indoor radon concentration of Guangdong province. Indoor PM10, PM2.5 and CO2 concentrations except CO were relatively high, in which PM10 and CO2 exceeded the standards up to 67% and 89% respectively. Apart from ordinary pollutants, hot spring hotels had higher222 Rn concentration in their rooms.
出处 《中国环境科学》 EI CAS CSCD 北大核心 2004年第6期650-653,共4页 China Environmental Science
基金 基金项目:广东省自然科学基金资助项目(980751 20003046) 广州市建设科技发展基金资助项目
关键词 可吸入颗粒物 二氧化碳 室内空气污染 respirable particulate matter radon carbon dioxide indoor air pollution
  • 相关文献

参考文献12

  • 1Lee S C, Li W M, Chan L Y. Indoor air quality at restaurants with different styles of cooking in metropolitan Hong Kong [J]. The Science of the Total Environment, 2001,279(1-3):181-193.
  • 2Lee S C, Guo H, Li W M, et al. Inter-comparison of air pollutant concentrations in different indoor environments in Hong Kong [J]. Atmospheric Environment, 2002,36(12):1929-1940.
  • 3Baek S O, Kim Y S, Perry R. Indoor air quality in homes, offices and restaurants in Korean urban areas-indoor/outdoor relationships [J]. Atmospheric Environment, 1997,31(4):529-544.
  • 4Liu Y S, Chen R, Shen X X, et al. Wintertime indoor air levels of PM10, PM2.5 and PM1 at public places and their contributions to TSP [J]. Environment International, 2004,30(2):189-197.
  • 5Lettner H, Hubmer R R, Steinh(a)usler F. Occupational exposure to radon in treatment facilities of the radon-spa Badgastein, Austria [J]. Environment International, 1996,22(Suppl.1):399-407.
  • 6Soto J, Fernandez P L, Quindos L S, et al. Radioactivity in Spanish spas [J]. The Science of the Total Environment, 1995, 162(2-3):187-192.
  • 7孙义俊.某温泉浴室中^(222)Rn及其子体浓度水平调查[J].中华放射医学与防护杂志,1998,18(6):435-436. 被引量:4
  • 8GB/T18883-2002,室内空气质量标准 [S].
  • 9王俊,刘红林,且华彬.温泉场所卫生标准制订的必要性[J].环境与健康杂志,2002,19(3):215-215. 被引量:1
  • 10Lee Thomas K C, Yu K N. Effects of air conditioning, dehumidification and natural ventilation on indoor concentrations of 222Rn and 220Rn [J]. Journal of Environmental Radioactivity, 2000,47(2):189-199.

同被引文献114

引证文献9

二级引证文献82

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部