期刊文献+

The automaticity of Mahaim fibre and its response to effective ablation

The automaticity of Mahaim fibre and its response to effective ablation
原文传递
导出
摘要 Background Typical accessory pathways (APs) of Wolf Parkinson White syndrome have been widely discussed in recent decades However, the characteristics of the special AP, Mahaim fibre, are not so clear It is known that these fibres have antegrade conduction only, long conduction time, decremental node like conduction and automaticity properties This study was to elucidate the automaticity of Mahaim fibre and its response to effective ablation Methods Thirteen patients with Mahaim fibre (ten atrioventricular and three atriofascicular accessory pathways) were subjected to electrophysiological study and radiofrequency ablation via catheter The incidence and characteristics of anautomatic rhythm originating from Mahaim fibre were observed during the whole procedure, especially during radiofrequency current delivery Results Repetitive and short run automatic rhythm (rate: 65-72 beats per minute), with a QRS morphology similar to that of clinical pre excited atrioventricular re entrant tachycardia (AVRT), occurred in two patients during sinus rhythm Conduction via Mahaim fibre was successfully eliminated by radiofrequency current Fourteen applications of RF were associated with irregularly accelerated automatic tachycardia of Mahaim fibre (with a sensitivity of 78%), lasting for 1 2-14 seconds However, such automatic tachycardia of Mahaim fibre did not occur during 54 failed applications of radiofrequency current Conclusions Mahaim fibre has the function of automaticity The accelerated automatic tachycardia of Mahaim fibre occur red during radiofrequency catheter ablation can be used as a predictor for successful procedure Background Typical accessory pathways (APs) of Wolf Parkinson White syndrome have been widely discussed in recent decades However, the characteristics of the special AP, Mahaim fibre, are not so clear It is known that these fibres have antegrade conduction only, long conduction time, decremental node like conduction and automaticity properties This study was to elucidate the automaticity of Mahaim fibre and its response to effective ablation Methods Thirteen patients with Mahaim fibre (ten atrioventricular and three atriofascicular accessory pathways) were subjected to electrophysiological study and radiofrequency ablation via catheter The incidence and characteristics of anautomatic rhythm originating from Mahaim fibre were observed during the whole procedure, especially during radiofrequency current delivery Results Repetitive and short run automatic rhythm (rate: 65-72 beats per minute), with a QRS morphology similar to that of clinical pre excited atrioventricular re entrant tachycardia (AVRT), occurred in two patients during sinus rhythm Conduction via Mahaim fibre was successfully eliminated by radiofrequency current Fourteen applications of RF were associated with irregularly accelerated automatic tachycardia of Mahaim fibre (with a sensitivity of 78%), lasting for 1 2-14 seconds However, such automatic tachycardia of Mahaim fibre did not occur during 54 failed applications of radiofrequency current Conclusions Mahaim fibre has the function of automaticity The accelerated automatic tachycardia of Mahaim fibre occur red during radiofrequency catheter ablation can be used as a predictor for successful procedure
出处 《Chinese Medical Journal》 SCIE CAS CSCD 2004年第12期1768-1771,共4页 中华医学杂志(英文版)
关键词 Mahaim fibre automaticity radiofrequency catheter ablation Mahaim fibre · automaticity · radiofrequency catheter ablation
  • 相关文献

参考文献10

  • 1SternickEB ,,SosaEA,WellensHJ ,etal.AutomaticityinMahaimfibers[].JCardiovascuElectrophysiol.2004
  • 2TebbenJohannsJ,,PfeifferD,LuderitzB ,etal.Radiofrequencycatheterablationofarightposterolateralatrioventricularaccessorypathwaywithdecrementalconductionproperties(Mahaimfiber)[].American Heart Journal.1993
  • 3TeoWS,YeeR,KleinGJ ,etal.Hypothesistestingasanapproachtotheanalysisofcomplextachycardias anillustrativecaseofapreexcitationvariant[].PacingClinElectrophysiol.1991
  • 4SternickEB,GerkenLM,VrandeclcM.Appraisalof"Mahaim"automatictachycardia[].JCardiovascElectrophysiol.2002
  • 5LiGQ,YangMQ,PaEHT ,etal.Radiofrequencycatheterablationforatrio fascicularfiberwithautomaticityinapatient[].ChinJCardiacArrhyth.2002
  • 6DavidsonNC,MortonJB,KalmanJ ,etal.LatentMahaimfiberasacauseofantidromicreciprocatingtachycardia:recognitionandsuccessfulradiofrequencyablation[].JCardivascElectrophysiol.2002
  • 7ZhouSH,MaJ,ChuJM ,etal.ElectrophysiologicalcharacteristicsofMahaimfiberandtreatmentbyradiofrequencycatheterablation[].ChinJCardiacArrhyth.1998
  • 8KleinLS,HackettFK,ZipesDP,MilesWM.RadiofrequencycatheterablationofMahaimfibersatthetricuspidannulus[].Circulation.1993
  • 9StellbrinkC,HalternG,SchauerteP ,etal.High frequencycurrentablationofaMahaimfiberatthetricuspidannulus[].Zeitschrift fur Kardiologie.1995
  • 10MounseyJP,GriffithMJ,MccombJM.RadiofrequencyablationofaMahaimfiberfollowinglocalizationofMahaimpathywaypotentials[].JCardiovascElectrophysiol.1994

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部