摘要 IEC 60076-11《干式变压器》标准草案的出台在国内干式变压器(电抗器)行业引起了较大反响,也引发了一些不当的争论。笔者结合多年从事变压器行业和绝缘行业工作的经验,主要针对IEC 60076-11《干式变压器》标准草案中的新增内容从运行环境和条件对干式变压器(电抗器)性能的影响、干式变压器(电抗器)对环境的影响、提高可靠性要求对干式变压器(电抗器)的影响几方面谈了谈自己的看法,供大家参考。 The enactment of draft standard IEC 60076 -11 'Dry - type transformer' aroused greater repercussion and also initiated some unsuitable arguments in domestic profession of dry type transformer (reactor). Aiming at the new content in draft standard IEC 60076 - 11 'Dry - type transformer', the author talked about own view from the influence of operating environment on performance of dry type transformer (reactor), the influence of dry type transformer (reactor) on environment, and the influence of raising the reliability requirements on dry type transformer (reactor), combined with the experience of being engaged in the work of transformer and insulation professions for many years.
出处 《电力设备》 2005年第2期48-50,共3页 Electrical Equipment
关键词 干式变压器 电抗器 标准草案 环氧树脂绕组 绕包绝缘绕组 dry - type transformer reactor standard draft epoxy resin winding wrapper insuktbn winding