摘要
在变风量空调及其控制系统动态仿真软件的基础上,根据ASHRAEStandard62-2001标准对于湿度控制的要求,分析了送风温度和冷媒水供水温度对空调区域相对湿度控制的影响.同时提出并分析了满足ASHRAEStandard62-2001标准对湿度控制要求的送风温度优化控制策略.
On the basis of dynamic simulation of variable air volume (VAV) air-conditioning systems and controls, this paper analyzed the effect of supply air and water temperature of VAV air-conditioning system on indoor humidity control, according to the relative humidity control requirement of ASHRAE Standard 62-2001. Meanwhile, this paper also brought forward and analyzed the optimal control strategy of supply air temperature satisfying the relative humidity control requirement of ASHRAE Standard 62-2001.
出处
《上海交通大学学报》
EI
CAS
CSCD
北大核心
2005年第2期216-219,共4页
Journal of Shanghai Jiaotong University
关键词
变风量
空调系统
送风温度
供水温度
湿度控制
Air conditioning
Control systems
Optimization
Temperature control
Ventilation