文中叙述了一种由可关断晶闸管(GTO)构成的电力系统无功功率发生器(ASVG)。描述了发生器的原理、计算机仿真分析、总体结构及实验结果。装置的原型已在实验室运行。证明调节灵活,反应快速,有广阔的发展和应用前途。
A novel static VAR generator which employs GTO is presented in the paper. Principle of the VAR. generator, computer simulation analysis, structure of the main circuit and results of experiment are described. A prototype of the VAR generator has been operating successfully in laboratory. It shows that the static VAR generator has rapid response ability and good control feature, and it has wide development and application prospect.