摘要
目的:了解上海市浦东新区42家医院消毒效果。方法:按照国标GB15982-1995、GB15981-1995、GBJ48-83的要求进行消毒效果调查。结果:医疗用品细菌总数合格率为80.36%,环境物表细菌,总数合格率92.86%,医疗用品HBsAg合格率为99.40%,环境物表HBsAg合格率为100.00%,环境物表大肠菌群合格率为99.49%,灭菌医疗器材合格率为97.14%,应用中消毒液细菌总数合格率为95.07%,空气细菌总数合格率为58.33%,高压锅和福尔马林消毒箱消毒效果合格率分别为100.00%、80.70%,医院污水合格率为53.84%,紫外线灯的辐照强度值合格率为90.74%。结论:浦东新区各医院消毒隔离效果尚可,但需加强医院污水、室内空气、福尔马林消毒箱及消毒液浸泡医疗用品的消毒隔离工作。
Objective:To survey the disinfection work of 42 hospitals in Pudong New Area. Methods:According to GB15982-1995. GB15981-1995. GBJ48-83. Results: The eligible rate of total bacterial count was 80. 36% in medical commodities, while 92. 86 % in objects' surfaces; the eligible rate of HBsAg was 99.4O% in medical commodities, while 100. 00% in objects' surfaces; the eligible rate of coli-group was 99.49 % in objects' surfaces; the eligible rate of sterilized medical supplies and applicanses was 97. 14 %; the eligible rate of totaI bacterial count of disinfectants in use was 95. 07 %; the eligible rate of operating rooms and mother-infancy rooms was 58. 33 %; the eligible rate of steamer sterilization facilities and formalin infectors were 100. 00 %.'80. 70 %; the eligib1e rate of hospital sewage disposal and ultravio1et radiation intensity were 53. 85 % and 90. 74 %. Conlusion: The disinfection work in hospitals of Pudong New Area is well, but some items such as hospital sewage disposal. air condition of operating rooms and mother-infancy rooms. disinfection effect of formalin disinfector and the disinfectant disinfected medical commodities should be improved.
出处
《上海预防医学》
CAS
1998年第8期361-363,共3页
Shanghai Journal of Preventive Medicine
关键词
医院消毒
合格率
医疗用品
细菌总数
毒效
效果调查
HB
福尔马林
隔离
灭菌
Bacterial contamination
Steam sterilization facility
Formalin disinfector
Ultraviolet radiation intensity value
Disinfection of hospital sewage