摘要
介绍一种与光学结构密切相关的辐射温度计辐通量的计算方法,可以定量分析辐射温度计的目标限制,探讨黑体辐射空腔对仪表标定精度、距离试验的影响,并可进一步深入研究黑体辐射空腔的积分发射率。
This paper introduces a calculation method for radiation flux of radiation thermometer which is closely related to the optical structure. It can be used to analyze the object limitation of the radiation thermometer quantitively and investigate the effects of black-body radiation chamber on calibration accuracy of the instrument and distance test. In addition, the integration radiation rate of blackbody chamber can be investigated further more.
出处
《自动化仪表》
CAS
北大核心
1993年第8期12-16,共5页
Process Automation Instrumentation