本文针对高压电机绝缘的特点,评述了各种预防性试验的方法及其各自优缺点,介绍了一种老化诊断的综合判定法──减点法。并结合试验中的体会,就一些试验现象进行解释。
Some preventive testing methods,and the advantages and defects of them are described in accordance with the characteristics of HV motor insulation,The method of point-reduction, a new comprehensive ageing diagnosis is introduced.The phenomena occurring in tests are explained,and the suggestion is offered on the standard in force in Baosteel of HV motor insulation.
出处
《宝钢技术》
CAS
1994年第2期59-63,共5页
Baosteel Technology