期刊文献+

大型预应力混凝土消化池结构的设计研究

Research on Structural Design of the Large Capacity Prestressed Concrete Digestor
下载PDF
导出
摘要 消化池是大型污水处理厂污泥处理工艺中必要的组成部分,它的特点是:容量大,内压高。消化池建后常年满水,并需保证污泥常温35℃,产生沼气有一定内气压。结构要求密闭,不渗水、不漏气。池壁不允许出现裂缝。池外要求做保温。本文主要结合高碑店污水处理厂一期工程中大型消化池的结构设计,通过工程实践总结,针对池壁环向预加应力设计,提出几点看法,供同行们探讨和参考。 Digester is an essential component part in mud treatment technology of a large sewage treatment plant. It's characteristic is huge capacity, high internal pressure. After the digester was built, water must be filled throughout the year, and the mud must be ensure for a normal atomspheric temperature at 35℃, thus to produce marsh gas which must have proper internal pressure. It's structure must be air tightness, no water percolation and no air leakage. Cracks are not allowed to appear on the disgestor walls. Heating insulations must be alone outside the digestor. This paper is intended to make a brief description of the structural design of digestor with large capacity in the first step engineering of Gao Bei- dian municipal sewage treatment plant of Beijing. Based on the summary of construction practice, some view points about the prestressed design of hoop stress of the tank wall are presented in this paper and it may be presented for discussion.
作者 高毓德
出处 《北京建筑工程学院学报》 1994年第2期12-17,共6页 Journal of Beijing Institute of Civil Engineering and Architecture
关键词 预应力混凝土 消化池 结构设计 digestor hoop tension stress continous wirecoiling gun spraying winding hoop prestress
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部