摘要
采用JP-1A极谱仪与计算机联机技术用卡尔曼滤波数学方法,解析以盐酸为支持电解质的铅(Ⅱ)和锡(Ⅲ)混合试液的极谱重叠波,同时用于地质样品测定,结果令人满意。
The overlapping polarographic wavcs of Pb(Ⅱ)and Sn(Ⅱ)in 1 mol·L ̄(-1)HCl electrotyte can be resolved by using Kalman filtering and a method for determingboth elements Simultancously has been developed and used to real sample determinationsuccessfully.
关键词
铅
锡
地质样品
卡尔曼滤波
Kalman filter,polarography,geological sample