摘要
用不同浓度甲胎蛋白(AFP)混合血清,制作成低、中、高三种不浓度质控血清,常规用于AFP放射免疫分析。采用logity─logx线性回归法进行数据处理。未知样品由logity=a+blogx计算出来。质量控制参数及质控血清测定值:r=≥0.99;RER为3.33±1.02%;ED70、ED50和ED30(μg/l)分别为31±5.32、86±11.56和182±27.95;三种质控血清(μg/l)分别为39.4±4.58(CV为11.6%)、164.8±14.76(CV为9%)和364±21.66(CV为6.26%)。以上参数及三组QC血清10次测定结果的平均值为基数或靶值,以±S、±2s、±3S为界限值作图。认为,该法能从标准曲线、质控样品和操作水平来有效地控制放射免疫测定AFP的质量。
Several mixed
serums containing AFP of different concentration were used to make 3kinds of quality control
serums,namely low, middling and high AFP concentration,which were routinelyapplied to AFP
determination by radioimmunoassay.Logit y-logx linear regression analysis was adopted
inprocessing data;the content of AFP in unknown speciments were calculated by logit
y=a+blogx. Linearregression coefficient of standard curve,response error
relationship,ED70,ED50,and ED30 were selectedas quality control parameters.The determined
values of quality control serums and parameters were asfollows:r≥0.99;RER=3.33±
102%;ED70=31±5.32μg/L;ED50=86±11. 56μg/L;ED30=182±27.95μg/L; three qulity
contral serums(μg/L)Were 39.4±4.58(cv=11.6%),164.8±14.76(cv=9%)and 364±2l.66
(cv=6.26%)respectively.Quality control charts were plottedrespectively in Which the average
value of 10 determined data from the same quality control serum orparameter was taken as
target value or the base,and the standard deviation as control limit.The authorsbelieve that the
quality control method can effectively control the quality of AFP determination
byradioimmunoassay through standard curve,quality control speciment amd operative level.