摘要 用不同浓度甲胎蛋白(AFP)混合血清,制作成低、中、高三种不浓度质控血清,常规用于AFP放射免疫分析。采用logity─logx线性回归法进行数据处理。未知样品由logity=a+blogx计算出来。质量控制参数及质控血清测定值:r=≥0.99;RER为3.33±1.02%;ED70、ED50和ED30(μg/l)分别为31±5.32、86±11.56和182±27.95;三种质控血清(μg/l)分别为39.4±4.58(CV为11.6%)、164.8±14.76(CV为9%)和364±21.66(CV为6.26%)。以上参数及三组QC血清10次测定结果的平均值为基数或靶值,以±S、±2s、±3S为界限值作图。认为,该法能从标准曲线、质控样品和操作水平来有效地控制放射免疫测定AFP的质量。 Several mixed serums containing AFP of different concentration were used to make 3kinds of quality control serums,namely low, middling and high AFP concentration,which were routinelyapplied to AFP determination by radioimmunoassay.Logit y-logx linear regression analysis was adopted inprocessing data;the content of AFP in unknown speciments were calculated by logit y=a+blogx. Linearregression coefficient of standard curve,response error relationship,ED70,ED50,and ED30 were selectedas quality control parameters.The determined values of quality control serums and parameters were asfollows:r≥0.99;RER=3.33± 102%;ED70=31±5.32μg/L;ED50=86±11. 56μg/L;ED30=182±27.95μg/L; three qulity contral serums(μg/L)Were 39.4±4.58(cv=11.6%),164.8±14.76(cv=9%)and 364±2l.66 (cv=6.26%)respectively.Quality control charts were plottedrespectively in Which the average value of 10 determined data from the same quality control serum orparameter was taken as target value or the base,and the standard deviation as control limit.The authorsbelieve that the quality control method can effectively control the quality of AFP determination byradioimmunoassay through standard curve,quality control speciment amd operative level.
作者 冯军 马永莉
出处 《承德医学院学报》 1994年第1期8-11,共4页 Journal of Chengde Medical University
关键词 放射免疫分析 甲胎蛋白 内质量控制 radioimmunoassay AFP quality control, internal Sanitation and Anti-epidemicStation,Change Prefeture
  • 相关文献

同被引文献8

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部