摘要
对70℃、100℃、150℃和200℃条件下存放的三种结构的Li/SOCl_2电池进行了观察和测定其失效时间,并与室温贮存的同种电池进行了对比,还讨论了结构、温度和失效时间的关系。
The observation of storage effect of different structure of Li/SOCl2 batteries was carried out respectively in 70℃,100℃,150℃ and 200℃. The failure time of the batteries was repc rted and compared with that in room temperature,relations between the structure, temperature and failure time were discussed.
出处
《电池》
CAS
CSCD
1994年第3期110-112,共3页
Battery Bimonthly
关键词
电池
技术分析
热失效
锂电池
Lithium Batteries Heat Failure. Li/SOCl_2