摘要 利用微波加热技术,在密闭容器内通过压力浸提、消解试样,能大大加快分析速度。本实验测定了不同煤样中的腐植酸总量,讨论了功率、时间、酸度等因素对分析结果的影响,并与标准方法相对照。用t-检验法及F-检验法检验,没有明显差异,结果令人满意。该法具有省时、省力、经济、不污染环境、宜于批量分析、便于普及推广等优点。 Using microwave-heating method, coal samples were digested with sodium pyrophoshatesodium hydroxide and were dispelled with potassium bichromate-sulfuric acid in the closed vessel.This paper has discussed the effect of analysis result by power, time and acidity etc.In different coal sample, humic acid amount was measured. Compared with classical method, Using t-test and F-test the result is satisfactory. This method has many advantages such as saving time, saving labour, saving money and not polluting environment.This method is appropriate for batch analysis and easy to spread.
出处 《分析测试学报》 CAS CSCD 1994年第2期74-78,共5页 Journal of Instrumental Analysis
关键词 微波加热 腐植酸 浸提 测定 Microwave-heating,Humic acid, Digestion.
  • 相关文献

参考文献4

二级参考文献3

  • 1杨先和,痕量分析,1987年,3卷,1期,50页
  • 2陈学德,中国环境监测,1989年,5卷,2期,20页
  • 3团体著者,环境监测分析方法,1986年

共引文献97

同被引文献1

  • 1中国土壤学会农业化学专业委员会.土壤农业化学常规分析方法[M]科学出版社,1983.

引证文献1