期刊文献+

填料精馏塔传质单元数的坐标变换求解

Coordinate Transformation Compution of the Number of Transfer Units in a Packed Distillation Column
下载PDF
导出
摘要 利用坐标变换原理,导出了计算填料精馏塔传质单元数的新公式。与现有的求传质单元数的公式比较,该式具有形式简单,适用于理想溶液各种进料状况以及某些二元恒沸精馏系统的优点。计算实例表明本文提出的方法可用于填料精馏塔传质单元数的精确求解。 The author uses the principle of coordinate trnsformation to develop a new equation for the calculation of the number of transfer units in a packed distillation column.Compared with the existing equation to calculate the number of transfer units,the new equation is simple and suitable for use under various feeding conditions of ideal solution and some binary azeotropic distillation systems.The calculation examples show that the method in this paper can be used for the exact compution of the number of transfer units in a packed distillation column.
作者 阮奇
出处 《福州大学学报(自然科学版)》 CAS CSCD 1994年第6期109-115,共7页 Journal of Fuzhou University(Natural Science Edition)
关键词 填料 精馏塔 传质单元 坐标变换 解析解 精馏塔 packed distillation column transfer unit coordinate transformation analytical solution
  • 相关文献

参考文献1

  • 1余国琮,杨志才,顾芳珍.精密精馏填料塔的稳态特性[J]化工学报,1980(02).

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部