期刊文献+

医用诊断X线机房空气中离子浓度的调查

INVESTIGATION ON AIR ION CONCENTRATION OF MEDICAL X-RAY ROOM
下载PDF
导出
摘要 对乌鲁木齐地区5所医院1所卫生防疫站的医用诊断X射线机房内空气中正负离子浓度进行了调查,结果表明:透视和摄片机房空气中正负离子浓度分别为474±118,312±104(个/cm3)和404±101,256±78(个/cm3).单极系数(n+/n-)分别为1.52和1.58。正离子浓度均高于对照组(P<0.01),n+/n-相当于对照组的1,37和1.42倍。开机后空气中正离子浓度显著高于开机前浓度,n+/n-开机后相当于开机前的1.66和1.59倍,呈现出X线机房空气中正负离子严重失调。提示应加强有害因素的防护。 The canon and anion concentrations of medical x-ray room of five hospitals and one sanitation and antiepidemic station were invstigated. It showed that the air cation and anion concentration of flouroscopy and x-ray mechine room were 474± 118, 312±104 and 404±101,256±78 (number/cm2), respectively. The unipolar coefficient (n-/n-) was respectively 1. 52 and 1. 58. The cation concentration was higher than collation (P<0. 01), n-/n- was 1.37 and 1.42 times of collation, respectively. Air cation coneentration after operation was significantly higher than that before operation, and n+/n- after operation was respectively 1. 66 and 1. 59 times of that before operation. The detuning between cation and ation was indicated. The protection to harmful factors was suggested.
出处 《干旱环境监测》 1994年第4期227-228,242,共3页 Arid Environmental Monitoring
关键词 正负离子 单极系数 X线机房 乌鲁木齐 Cation and Anion Unipolar coefficient X-ray room Urumqi
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部