摘要
通过对锅炉水冷壁管爆口宏观形貌和显微组织特征分析,确认锅炉水冷壁管爆裂属于高浊蠕变失效。
t is identified by examinimg the macro-morphology and micro-structure of the broken water cooled wall pipe of the boiler at its cracking hole that the cracking of the wall pipe is caused by the failure of high temperature creep deformation.