期刊文献+

高压电机定子绕组的超低频耐压试验与遥控 被引量:2

Extra Low Frequency Voltage Withstand Test of Motor Stator Winding of HV Generator and Remote Control
下载PDF
导出
摘要 超低频0.1Hz交流耐压试验与工频交流耐压试验,当合理确定等价系数β后是完全等价的.超低频0.1Hz交流耐压试验,有设备容量小、灵巧方便、相对延长试品电机寿命并可代替直流耐压试验的优点,应大力推广.现介绍研制的超低频0.1Hz耐压试验装置,采用遥控的交流耐压试验,根本上解决了高压试验人员的安全.遥控应推广至高压试验与测量中. if thc cquivalcnt cocfflcicnt gis rationally cltermincd the test of extra low frcqucncy 0.1Hz Ac voltagc-withstund is totally cquialcnt with the tcst of 50 HZ Ac voltage-withstand the test of 0.1 Hz Ac voltaage-withstand has the advantage of flcxibility and low size of cquipment,also it could prolong the scrvicc lifc of motor so it has a promising future. The afticle describcs the testing cqquipment of cxtra frcqucncy 0.1 HZ voltagc-withstand and the remotc control of Ac voltagc-withstand test, which rcdically solve the problem of the safcty of high voltage testing worker. The rcmote coutrol should be developpcd in thc tcshng and measure of high voltage.
出处 《高电压技术》 EI CAS CSCD 北大核心 1994年第4期72-75,共4页 High Voltage Engineering
关键词 超低频 耐压试验 遥控 高压电机 定子绕组 extra frquency voltage-withstand test remotc contron insulation